EN - 10
5 Putting into operation
ABIMIG
®
XX0/XX5
Wear parts for ABIMIG
®
XX0
Wear parts for ABIMIG
®
XX5/XX7
5.2 Mounting the wire guide
1
Transition piece
2
Counter nut
3
Tip adaptor
4
Contact tip
5
Gas nozzle
Fig. 1
Equipping the torch
ABIMIG
®
XX0
5
4
3
2
1
NOTICE
• The counter nut and the tip adaptor are attached to the torch neck by
means of a left-handed thread.
• The left-handed thread is marked at the tip adapter, at the counter nut
and at the torch neck with a groove.
• During mounting screw the tip adapter tightly against the torch neck.
Then screw the counter nut tightly against the tip adaptor, in order to
secure a tight connection.
1
Transition piece
2
Tip adaptor
3
Contact tip
4
Gas nozzle
Fig. 2
Equipping the torch
ABIMIG
®
XX5/XX7
4
3
2
1
NOTICE
• The tip adapter is fastened to the torch neck by means of a right-handed
thread.
• During mounting screw the tip adapter tightly against the torch neck.
NOTICE
• Only use gas-tight, plastic-insulated wire guides to ensure a secure
shielding gas cover and a defined current contact.
• Bare liners give rise to a loss of shielding gas.