EN - 4
3 Product description
ABIMIG
®
XX0/XX5
2.3 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
• Gas supply
Further measures can be found in the operating instructions for the power
source or the documentation for other peripheral devices.
3 Product description
3.1 Technical Data
NOTICE
Describes the risk of impairing work results or potential material damage to
the equipment.
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and
material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without
authorisation.
• The device may only be used by qualified personnel (in Germany, see
TRBS 1203).
Transport and storage
- 25 °C to + 55 °C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient conditions during operation
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Wire types
Commercially available round wires
Voltage rating
113 V peak value
Protection type of the machine side connections
(EN 60 529)
IP3X
Control device in handle
for 42 V and 1 A
Tab. 2
General torch data according to EN 60 974-7