EN - 11
ABIMIG
®
XX0/XX5
5 Putting into operation
5.2.1 Liner
ABIMIG
®
XX0/XX5 product range and ABIMIG
®
A XX5 GRIP product range
For use of steel wires with undivided wire guide.
1
Lay down the BIKOX
®
cable assembly straight and unscrew gas nozzle and
contact tip from the torch neck.
2
Unscrew nut from the central connector or direct connector and slide liner
through the BIKOX
®
cable assembly up to the retaining nipple.
3
Screw down nut again, tighten using the ABIMIG wrench and cut off excess
length of the liner flush with the tip adaptor.
4
Screw in contact tip and gas nozzle.
ABIMIG
®
XX0 T/XX5 T product range and ABIMIG
®
A T XX5 LW product range
For use of steel wires with divided wire guide.
1
Lay down the BIKOX
®
cable assembly straight and unscrew rotating or
repluggable torch neck.
2
Unscrew nut from the central connector and slide liner through the BIKOX
®
cable assembly up to the retaining nipple.
3
Screw down nut again, tighten using the ABIMIG wrench and cut off excess
length at the handle threaded part so that it protrudes 2 mm.
4
Screw down rotating or repluggable torch neck again at the handle.
NOTICE
• New and unused liners must be abridged to the actual length of the
cable assembly.