TIG cold-wire feeder
6 Putting into operation
BAL.0415.0 • 2018-10-22
EN - 11
6.3 Front panel
Display indicators
1
Display for parameter indicator
2
Display for parameter value
3
Feed rate [m/min]
4
Parameter time [sec]
5
Knob for setting parameters
6
Parameter selection
7
Function type selection
8
Wire feed
9
Wire retraction/function
button
Fig. 5
Front panel display
1
2
3
4
5
6
7
8
9
Left display (1)
Right display (2)
Indicator
Description
Indicator
Description
SPE
Wire feed rate
(0.2 – 8.0 m/min)
Value between
0.2 and 8.0
(top) in m/min
dt
Wire feed delay time
(0 – 3 sec.)
Value between
0 and 3.0
(bottom) in seconds
re
Wire retraction time (off – 3 sec.)
Value between
Off and 3.0
(bottom) in seconds
ton
Wire feed with interval (0.1 – 5 sec.)
Only if function type
‘interval’ has
been selected
Value between
0.1 and 5.0
(bottom) in seconds
tof
Wire feed interval break
(0.1 – 5 sec.)
Only if function type
‘interval’ has
been selected
Value between
0.1 and 5.0
(bottom) in seconds
run
While welding with a wire feed
- - -
During the break with an interval
Tab. 9
Display indicators after switching on