Case studies
System Manual 2CKA000073B9795
│70
Apartment (with actuator):
The PoE switch and routing are enabled in the apartment. That is why no additional devices are
necessary for this function.
The indoor station in the version is intended for LAN connection.
The entrance door is equipped only with an automatic door opener. That is why an IP actuator
is required which accepts the digital opening command and switches the door opener.
Also the light in a room is to be switched via the IP actuator.
– If the light is to be switched in additional rooms via IP actuators, additional actuators are
required (one each for 2 switching connections).
P E
o
Fig. 47: Overview: Apartment (with actuator)
PoE
LA
N
GN
D
DC
+
LA
N
LA
N
LA
N
LA
N
LA
N
LA
N
LA
N
GN
D
DC
+
IN
LO
C
K
+
LO
C
K
-
Fig. 48: Connection: Apartment (with actuator)