ABB Smart Скачать руководство пользователя страница 10

 

 

2TLC172188M0201, rev. H 

10 

www.abb.com/lowvoltage 

2012-01-03  

3.2 

SM2 – Pushbutton unit 

 

Application 

The SM2 stop unit is used together with Smart Logger to give a stop signal without electrical connection to 
machines or control systems. SM2 is connected to any of the I/O connectors on Smart Logger.  

The pushbutton on the underside of SM2 initiates stop time or intermediate time measurement when it is pressed 
or released, depending on the settings of the New measurement form in Smart Manager. When the in signal of 
SM2 is set to be active high, the unit can be used to measure the stop times of emergency stops, program stops, 
safety mats, contact strips and the like. The ‘stop device’ is pushed by the means of the pushbutton on the 
underside of SM2. The stop timing will start when this pushbutton is pressed. 

When the in signal of SM2 is set to be active low, the unit can be used for the measurement of stop times on two-
hand units, and hold to run/enabling devices. Hold in for example one button on the two-hand unit by means of the 
pushbutton on the underside of SM2. The measurement starts when the pushbutton on SM2 is released, i.e. when 
the pushbutton on the two-hand unit is released. 

General 

When using the SM2 stop unit it is important that the correct procedure is carried out in order to obtain the best 
values possible without electrical connection to the machine. The quickest and most distinct movement possible 
should always be made, both during the actuation of stop devices, emergency stop buttons, and ”on” buttons with 
hold to run function, such as two-hand units. A quick movement minimizes the small time difference between the 
response of the stop device button and the button in the stop unit starting the 
measurement. 

Indication 

The LED on top of SM2 is for example used to give manual stop signal at the same 
position for a machine each time. The LED is lit by the output signal from Smart 
Logger to SM2, the conditions can be set in Smart Manager. 

Measurement on two-hand device 

The diagram to the right illustrates an appropriate movement during the measurement 
of stop times initiated by two-hand units with mushroom buttons. The SM2 stop unit 
should be drawn quickly and distinctly to the side, that is, at right angles to the 
inherent movement of the two-hand button.  

Technical specifications 

 

Manufacturer:

 

ABB AB / JOKAB SAFETY 

Designation:

 

SM2

 

Article number: 

2TLA070300R0200 

Operating voltage:

 

Supplied from Smart Logger

 

Size:

 

100 x 50 x 25 mm (L x W x H)

 

Weight:

 

0.2 kg

 

Colour:

 

Black/Yellow

 

 

Содержание Smart

Страница 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Sweden www abb com lowvoltage Original instructions Smart Safety and Motion Analyser Tool...

Страница 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete deter...

Страница 3: ...ng a measurement 30 4 9 Displaying measurements 33 4 10 Calculating stop time and safety distance 36 4 11 Compare measurements 37 4 12 Save measurements 39 4 13 Load measurements 40 4 14 Importing and...

Страница 4: ...ring and analysing mainly moving machine parts but also machine systems in general Different sensors and transducers can be connected to Smart to measure movement and forces and different stop units c...

Страница 5: ...very year 4 To guarantee the accuracy of the safety distance calculated using Smart Manager the user must use appropriate values in the formula for the calculation and the user must also make sure tha...

Страница 6: ...cable Communication with computer Smart Logger communicates with the computer using the USB cable in the PC connector on top of the unit Starting Smart Logger Make sure that Smart Logger is turned of...

Страница 7: ...unit connectors 7 5 3 and 1 have the signals Q0 Q3 on pin 2 of the respective connectors The in signals I0 I7 are on pin 4 and 5 on the respective connectors according to the table on the panel on top...

Страница 8: ...machine system Connection of two wire analogue sensor to I9 Pulse sensor To measure motion speed and position a pulse sensor SM5 SM7 is connected to Smart Logger The pulse sensors have a resolution of...

Страница 9: ...cases is correct but in some special situations the actual stop time of the machine can be slightly less than the calculated stop time of the program The used algorithm is specially adapted to be cor...

Страница 10: ...n on the two hand unit is released General When using the SM2 stop unit it is important that the correct procedure is carried out in order to obtain the best values possible without electrical connect...

Страница 11: ...of program stops safety mats and contact rails etc The NC outputs are connected to the stop inputs from gate switches two hand units emergency stops and three position devices etc The maximum switchi...

Страница 12: ...using should be adjusted so that the machine movement takes place in line with the alignment of the wire The connection cable of SM5 is connected to the encoder connector I8 on Smart Logger Operation...

Страница 13: ...using should be adjusted so that the machine movement takes place in line with the alignment of the wire The connection cable of SM5 is connected to the encoder connector I8 on Smart Logger Operation...

Страница 14: ...ip and disturbances from dirt The connection cable of SM7 is connected to the encoder connector I8 on Smart Logger Operation The transducer utilises a digital incremental pulse encoder with a resoluti...

Страница 15: ...is activated rotated it interrupts the light curtain 8 Start the measurement in Smart Manager and then start the machine to be monitored 9 When the required point on the machine cycle is reached for...

Страница 16: ...be switched off when not in use In order to ensure optimized performance batteries must be fully charged prior to stopping measurements be taken The SM11 stop flag unit is specifically designed to be...

Страница 17: ...and the computer SM6 2TLA070300R0600 24 VDC power supply for Smart Logger SM9 2TLA070300R0900 Carrying case for Smart SM13 2TLA070300R2300 Battery pack for Smart Logger Can be used instead of SM6 to...

Страница 18: ...new computers If you don t have Net Framework installed you do the following Run the file dotnetfx exe in the folder dotNET Framework on the installation CD It can also be installed by running Windows...

Страница 19: ...ick on the button Start if the server isn t already running computername is the name of your computer in the network and can for instance in Windows 2000 be found in the Control Panel System under Net...

Страница 20: ...mart Manager Run the file SmartSetup msi in the folder Smart Manager on the installation CD and the installation program for Smart Manager will be started Click Next Read through the license agreement...

Страница 21: ...tage 2012 01 03 Change the installation folder if you want a different folder than the default Select if you want Smart Manager to be available for all users on the computer or only your own user Clic...

Страница 22: ...gger The following series of pictures describes the installation procedure on Windows XP Please note that the messages displayed on Windows 2000 or any other operating system will be slightly differen...

Страница 23: ...om lowvoltage 2012 01 03 When the drivers for Smart Logger have been installed the Found New Hardware Wizard will continue to install the USB serial port COM port emulation driver Select not to connec...

Страница 24: ...or you have the installation CD on your hard drive select the file FTDIPORT INF in the folder Drivers on the installation CD When the installation is finished you can find which COM port number Smart...

Страница 25: ...2TLC172188M0201 rev H 25 www abb com lowvoltage 2012 01 03 Manager Smart Logger appears as an additional COM port with the label USB Serial Port and the port number in parenthesis under the Ports node...

Страница 26: ...ause Smart Logger is connected to another communication port When Smart Logger is connected via the USB cable to the computer the computer automatically gives it the next free communication port numbe...

Страница 27: ...to other measurements Calculations On the calculations form different calculations can be performed to get a stop time based on several measurements and calculate safety distance from the machine Sav...

Страница 28: ...t can be calibrated The button Edit analogue conversion shows a form where the analogue input can be converted to show any units and values when displayed in the graph The button OK closes the form 4...

Страница 29: ...of the two currents should be as close to 20 mA as possible and the smaller current as close to 4 mA as possible Calibration of I9 1 Click the button Reset I9 This resets any previous calibrations and...

Страница 30: ...in mm s Analogue input I9 shows the current value for the analogue input on I9 Analogue input I10 shows the current value for the analogue input on I10 The position encoder can be reset to zero with t...

Страница 31: ...t to consider the conditions of the current measurement phase as fulfilled and move on to the next phase regardless of whether the conditions have been met or not The button Abort aborts the current m...

Страница 32: ...the condition is ignored I9 the phase is activated when the set condition for the analogue input I9 is met The button shows if the change in the analogue value the derivative should be positive or ne...

Страница 33: ...ow Stop time data If the stop time can be calculated a table containing stop time data is shown in the top right corner of the graph window The column Stop signal shows the speed and position at the m...

Страница 34: ...ws move the graph window Up down affects the selected graph Right left affects all visible graphs With the double arrows the window is moved to the beginning or end of the measurement The buttons Y zo...

Страница 35: ...hange signal names shows a form where the digital in and out signals can be renamed Layers shows a form where the current graph window can be saved as a template and used to compare with other measure...

Страница 36: ...rmation The list to the right displays the stop times of the selected measurements If no measurements have been selected the stop time of the current measurement is shown Beneath the list the minimum...

Страница 37: ...ceiving the output signal from the protective equipment t2 is influenced by various factors e g temperature switching time of valves ageing of components 4 11 Compare measurements To compare measureme...

Страница 38: ...ndow and load the next measurement The curves are shown on top of each other with different zoom 6 Repeat no 4 5 for the measurements you want to have in the background When you perform no 4 the zoom...

Страница 39: ...series In the textbox Measurement performed by the person company who performed the measurement is entered The textbox Date displays the date and time of the measurement Smart hardware ID shows the I...

Страница 40: ...cting which column you want to filter on in the leftmost drop list what type of condition you want in the next drop list and what value you want for the condition in the following textbox If you want...

Страница 41: ...les Export To export measurements from Smarts database to the external database you select the measurements you want to export in Smarts database and click on the button Export The measurements are th...

Страница 42: ...ile name file type and where to save the file There are three alternatives Bmp Jpg and Gif Bmp files are uncompressed and take up large disc space Jpg and Gif are formats that compress the images whic...

Страница 43: ...2TLC172188M0201 rev H 43 www abb com lowvoltage 2012 01 03...

Страница 44: ...2TLC172188M0201 rev H 44 www abb com lowvoltage 2012 01 03...

Отзывы: