Application
US
SU
Coriolis Interface (Gas)
X
X
ENRON Interface
X
X
LevelMaster
X
X
Liquid Coriolis Interface
X
X
NGC Client
X
X
Pump Interface
X
X
Therms Master
X
X
Therms Slave
X
X
Wireless Remote I/O
X
X
XIO Interface
X
X
XMV Interface
X
X
2.3.2.2
Application licensing (credit key)
The RMC must have sufficient available licensing credits to add (instantiate) and activate new
applications. Each application requires one or more credits of a specific type.
Add or remove applications from the licensed applications list as needed. Four (4) general credits are
included in the RMC. Purchase additional license credits for additional applications as needed. These
credits run the various applications available.
IMPORTANT NOTE:
Click
Help
on the Application/License Management tab for additional
information.
To determine if you must purchase additional credits:
1.
Insert the credit key into your laptop’s USB port.
2.
Launch PCCU and click
Entry
to connect with the controller in Entry mode.
3.
Click the top item on the navigation tree, then click
Application/License Management
. The
Application/License Management tab displays.
4.
Click
Credit/App Info
to display the Applications Credits Information screen. Locate the
application on the list. Then view and take note of the required credit type for that application.
5.
Click
Close
. The Application/Licensing Management tab displays again.
6.
View available and surplus credits in the Device Credits window.
7.
View available credits in the Key Credits window.
IMPORTANT NOTE:
If the credits on the device or the key are insufficient or not of the required
type, call
1-800-442-3097
and choose
Option 1
to purchase additional credits. Request the
specific type of credit you need, and the number of credits. See the last page of this manual for
contact information.
2.3.3
Configuration files
The configuration files contain the configuration or settings required for the operation of the RMC and
its applications. Configuration files can include initial (factory-defined) or user-defined settings or
parameters. The RMC contains the following configuration files:
–
Factory configuration is the ABB default factory configuration, or a customer-specific
configuration programmed into the factory folder during final assembly. The factory
configuration is read-only and stored in persistent memory. It can only be updated at the
factory.
–
Startup (cold) configuration is used for a cold restart of the device or when a configuration
package is sent to the device by the PCCU loader. The startup configuration is stored in the
tfCold directory and can be modified or updated as needed.
–
Running (warm) configuration is used by the device during normal operation. The running
configuration is stored in the tfData directory and can be modified or updated as needed.