![ABB Relion REC670 Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/abb/relion-rec670/relion-rec670_product-manual_3381059128.webp)
Software options
Ordering no
#3
Notes and rules
No option
X00
All fields in the ordering form do
not need to be filled in.
High impedance differential protection - 3 blocks
1MRK004001-AB
A02
A02 only in A30/B30/D30, A07
only in C30
High impedance differential protection - 6 blocks
1MRK004001-AG
A07
Stub protection
1MRK004001-VG
B25
B25 only in B30/C30
1MRK004001-VK
B27
B27 only in A30/D30
Sensitive directional residual overcurrent and power protection
1MRK004001-CT
C16
Directional power and voltage restrained overcurrent protection
1MRK004001-VL
C35
Current and breaker failure protection - 1 circuit breaker
1MRK004001-US
C51
Only one type of Current and
breaker failure protection can be
ordered.
C51 only in A30/D30; C52 only in
B30; C53 only in C30
Current and breaker failure protection - 2 circuit breakers
1MRK004001-UT
C52
Current and breaker failure protection - 1 1/2 circuit breaker
1MRK004001-UU
C53
Voltage protection - 2 buses
1MRK004001-DB
D02
Frequency protection - station
1MRK004001-EA
E01
General current and voltage protection
1MRK004001-FA
F01
Fuse failure supervision based on voltage difference
1MRK004001-HC
G03
Autorecloser, 1 circuit breaker
1MRK004001-GD
H04
Only one type of Autorecloser
can be ordered.
H04 only in A30/D30, H05 only in
B30, H06 only in C30
Autorecloser, 2 circuit breakers
1MRK004001-GE
H05
Autorecloser, 3 circuit breakers
1MRK004001-GF
H06
Voltage control, single transformer
1MRK004001-GL
H11
H11 and H15 only in
A30/B30/D30
H16 and H18 only in C30
Only one type of voltage control
can be ordered.
Voltage control, parallel transformers
1MRK004001-GM
H15
Voltage control, single transformer, 2 control blocks
1MRK004001-GN
H16
Voltage control, parallel transformers, 2 control blocks
1MRK004001-GP
H18
Scheme communication
1MRK004001-KC
K01
Transformer insulation loss of life monitoring
1MRK004001-KM
M21
IEC 62439-3 Parallel redundancy protocol
1MRK004001-PP
P23
Options P23 and P24 require two
SFPs placed in pairs.
IEC 62439-3 High-availability seamless redundancy
1MRK004001-PR
P24
IEC 61850-9-2 Process Bus communication, 8 merging units
1MRK004001-PT
P30
Synchrophasor report, 8 phasors
1MRK004001-PV
P32
P32 only in A30/B30/C30
Selection for
position #3
Language
Ordering no
#4
Notes and rules
First local HMI user dialogue language
HMI language, English IEC
1MRK002930-AA
B1
Additional local HMI user dialogue language
No additional HMI language
X0
HMI language, English US
1MRK002920-UB
A12
Selection for
position #4
B1
Casing
Ordering no
#5
Notes and rules
1/2 x 19" rack casing, 1 TRM
1MRK000151-VA
A
Only for A30/B30/D30
3/4 x 19" rack casing, 1 TRM
1MRK000151-VB
B
3/4 x 19" rack casing, 2 TRM
1MRK000151-VE
C
1/1 x 19" rack casing, 1 TRM
1MRK000151-VC
D
Only for A30/B30/D30
1/1 x 19" rack casing, 2 TRM
1MRK000151-VD
E
Selection for
position #5
1MRK 511 404-BEN A
Bay control REC670 2.2
Product version: 2.2.1
128