![ABB PVS300 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/abb/pvs300/pvs300_product-manual_4153031.webp)
Operation basics and hardware description 31
Type designation label
The type designation label is located on the right hand side of the inverter.
Type designation key
The type designation contains information on the specifications and configuration of
the inverter. You find the type designation on the type designation label attached to
the inverter. The first digits from the left express the basic configuration, for example
PVS300-TL-3300W-2. The final digits are reserved for optional selections. The type
designation selections are described below.
1
Product series
2
Construction (TL = Transformerless)
3
Nominal output power [W]
4
Nominal output voltage (2 = 200 - 240 V AC)
Solar Inverter
PVS300-TL-8000W-2
IP55, outdoor
MYYWWRXXXX
-25°C to +60°C S/N MYYWWRXXXX
Protection Class I
3AUA0000082992
Overvoltage Cat. III 3AUA0000082992
DC Input
AC Output
V
DC,max
900 V
V
AC,r
230 V
V
MPP,min
335 V
f
r
50
Hz
V
MPP,max
800
V
Cos
1
P
PV,max
8900 W
P
AC,r
8000
W
I
DC,max
25.4 A
I
AC,max
37.7 A
Grid monitoring in compliance with:
VDE0126-1-1:2006-02, RD1663/2000, DK5940 ed2.2
Made in EU
ABB OY,
www.abb.com
www.abb.com/solar
RoHS
2002/95/EC
No. Description
1
Type designation
2
Degree of protection
Operating temperature range
Classification of protection against
electric shock by IEC 62103
Category of protection against over
voltage of atmospheric origin or due to
switching by EN60664-1
3
Serial number and barcode
Material number and barcode
4
Ratings
5
Warnings, other information
6
Compliance markings
1
2
3
5
6
4
1
2
3
4
Содержание PVS300
Страница 1: ...ABB solar inverters Product manual PVS300 string inverters ...
Страница 4: ......
Страница 9: ...Table of contents 9 Further information ...
Страница 10: ...10 Table of contents ...
Страница 34: ...34 Operation basics and hardware description ...
Страница 48: ...48 Planning the installation ...
Страница 76: ...76 Installation checklist ...
Страница 110: ...110 Troubleshooting ...
Страница 120: ...120 Technical data ...
Страница 122: ...122 Dimension drawing 3AUA0000094904 ...
Страница 123: ...Dimension drawing 123 Required clearances for cooling ...
Страница 124: ...124 Dimension drawing ...
Страница 126: ...126 Navigation map The navigation map ...
Страница 127: ...Navigation map 127 ...
Страница 128: ...128 Navigation map ...
Страница 130: ...3AUA0000096321 Rev B EN EFFECTIVE 2013 03 14 Contact us www abb com solar ...