WaterMaster
Electromagnetic flowmeter
2 Parameter Tables
54
IM/WMPBST–EN Rev. B
24 / 8
SIMULATION_MODE
Internal parameter for simulation.
0: Off
1: Flow Velocity
2: Q
3: Q%
5: Pulse 1
6: Pulse 2
7: Logic 1
8: Logic 2
9: Logic 3
Unsigned 8
1
D
r,w / C / a
Off
25 / 9
SIMULATION_FLOW_VELOCITY
Internal flow velocity simulation value.
Min: TB5.SIMULATION_FLOW_VELOCITY_RANGE_LOWER
Max: TB5.SIMULATION_FLOW_VELOCITY_RANGE_UPPER
Unit: TB1.VELOCITY_UNIT
Float
4
D
r,w / C / a
0
26 / 10
SIMULATION_VOLUME_FLOW
Internal volume flowrate simulation value.
Min: TB5.SIMULATION_VOLUME_FLOW_RANGE_LOWER
Max: TB5.SIMULATION_VOLUME_FLOW_RANGE_UPPER
Unit: TB1.VOLUME_FLOW_UNITS
Float
4
D
r,w / C / a
0
27 / 11
SIMULATION_FLOW_RATIO
Internal volume flowrate percentage simulation value.
Min: -200
Max: 200
Unit: %
Float
4
D
r,w / C / a
0
28 / 12
SIMULATION_PULSE
Frequency to simulate on Digital Outputs 1 and 2.
Min: 0
Max: 5250
Unit: Hz
Float
4
D
r,w / C / a
0
29 / 13
SIMULATION_LOGIC_1
State to simulate on Logic Output 1.
0: Off
1: On
Unsigned 8
1
D
r,w / C / a
Off
30 / 14
SIMULATION_LOGIC_2
State to simulate on Logic Output 2.
0: Off
1: On
Unsigned 8
1
D
r,w / C / a
Off
Abs. Idx /
Rel. Idx
Variable Name / Brief Description
Data Type
Size
Store
Access /
Usage /
Transport
Default