2 Parameter Tables
8
IM/WMPBST–EN Rev. B
63 / 47
MASK_OVERRANGE_103
Mask for the Overflow 103% alarm.
0: Disabled
1: Enabled
Unsigned 8
1
S
r,w / C / a
Enabled
64 / 48
UNUSED
Unused parameter.
–
–
–
–
–
65 / 49
UNUSED
Unused parameter.
–
–
–
–
–
66 / 50
FLOWRATE_LIMIT_MIN_ALARM
Flowrate for min. flow alarm.
Min: 0
Max: 130
Unit: %
Float
4
S
r,w / C / a
0
67 / 51
FLOWRATE_LIMIT_MAX_ALARM
Flowrate for max. flow alarm.
Min: 0
Max: 130
Unit: %
Float
4
S
r,w / C / a
110
68 / 52
DATA_EXCHANGE_ACTIVE
Flag set when the device is cyclically exchanging data with a master.
0: Inactive
1: Active
Unsigned 8
1
D
r / C / a
Inactive
Abs. Idx /
Rel. Idx
Variable Name / Brief Description
Data Type
Size
Store
Access /
Usage /
Transport
Default
Table 2.2 Slot 0 – Physical Block (Continued)