2 Parameter Tables
IM/WMPBST–EN Rev. B
41
33 / 17
SENSOR_ID
Sensor ID number.
Unsigned 32
4
D
r / C / a
1
34 / 18
SENSOR_SAP_ERP_NUMBER
Sensor SAP / ERP number.
VisibleString
20
D
r / C / a
’? ’
35 / 19
TERM_BOARD_SW
Remote sensor memory version number.
VisibleString
20
D
r / C / a
’? ’
36 / 20
SENSOR_FIRST_CAL_DATE
The date of the sensor initial calibration.
VisibleString
20
D
r / C / a
’? ’
37 / 21
SENSOR_LAST_CAL_DATE
The date the sensor was last calibrated.
VisibleString
20
D
r / C / a
’? ’
38 / 22
SENSOR_CAL_CERT_NO
Factory-assigned certificate of calibration number.
VisibleString
20
D
r / C / a
’? ’
39 / 23
SENSOR_FIRST_CAL_LOCATION
The initial location where the sensor was calibrated.
0: Stonehouse
1: Göttingen
2: Warminster
3: Moorebank
4: Shanghai
5: Burlington
6: Not Specified
Unsigned 8
1
D
r / C / a
Stonehouse
40 / 24
SENSOR_LAST_CAL_LOCATION
The last location where the sensor was calibrated.
0: Stonehouse
1: Göttingen
2: Warminster
3: Moorebank
4: Shanghai
5: Burlington
6: Not Specified
Unsigned 8
1
D
r / C / a
Stonehouse
41 / 25
SENSOR_CALIBRATION_MODE
Used to distinguish the calibration type of the sensor between ProcessMaster and
WaterMaster types.
0: WaterMaster
1: ProcessMaster
Unsigned 8
1
D
r / C / a
WaterMaster
42 / 26
ELECTRODE_MATERIAL
Material type of the sensor electrodes.
0: Stainless Steel
1: Hastelloy C4
2: Hastelloy C276
3: Titanium
4: Tantalum
5: Hastelloy B3
6: Platinum Iridium
7: Duplex Steel
8: Nickel
9: St. Steel 316TI
10: Hastelloy C(DL)
11: Tungsten Carbide
12: Hastelloy C22
13: Super Austenitic Steel
14: Other
Unsigned 8
1
D
r / C / a
Stainless Steel
Abs. Idx /
Rel. Idx
Variable Name / Brief Description
Data Type
Size
Store
Access /
Usage /
Transport
Default
Table 2.11 Slot 9 – Transducer Block 2 – Device Info (Continued)