7.2.3 Using multitasking programs
Overview
In a system with the option
Multitasking
installed, you may have one or several
programs running in parallel, for instance in a
MultiMove
cell with more than one
robot where each robot has its own task and program (multitasking).
Manually set up tasks
Tasks need to be set up in order to run as planned. Normally, all tasks are set up
on delivery. Setting up tasks is done by defining system parameters of the type
Controller
. For information about system parameters, see
Technical reference
manual - System parameters
.
You need detailed information to set up tasks manually, see your plant or cell
documentation for details.
How tasks are run
Tasks may be defined as Normal, Static, or Semistatic. Static and Semistatic tasks
are automatically started as soon as a program is loaded into that task.
Normal tasks are started when you press the
Start
button of the FlexPendant, and
stopped when you press the
Stop
button.
Load, run, and stop multitasking programs
Use the following procedure to load, run, and stop multitasking programs.
1 Make sure there is more than one task set up. This is done using system
parameters, see
Technical reference manual - System parameters
.
2 Load programs to the respective task using
Operate
or
Code
. This is
described in the section
Loading programs to a task on page 191
.
3 If one or more task should be disabled, on the status bar, tap the QuickSet
menu, select the Execution tab, and disable the required tasks in the
Enable/Disable tasks
section.
Disabling the tasks can be done only in manual mode.
4 Start program execution by pressing the
Start
button on the FlexPendant.
All the active tasks are started.
5 Stop program execution by pressing the
Stop
button on the FlexPendant.
All the active tasks are stopped.
Continues on next page
190
Operating manual - OmniCore
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
7 Running in production
7.2.3 Using multitasking programs
Содержание OmniCore S Series
Страница 1: ...ROBOTICS Operating manual OmniCore ...
Страница 2: ...Trace back information Workspace RW 7 1 version a5 Checked in 2020 10 25 Skribenta version 5 3 075 ...
Страница 8: ...This page is intentionally left blank ...
Страница 22: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 60: ...This page is intentionally left blank ...
Страница 64: ...This page is intentionally left blank ...
Страница 208: ...This page is intentionally left blank ...
Страница 234: ......
Страница 235: ......