Limitations
Besides service routines,
Call Routine
applies to all routines with the following
criteria:
•
Must be a procedure with empty parameter list. This means not a function
and not a trap routine.
•
Must be in the task scope, not local. If the procedure is local in a module the
scope is restricted to that module, and the procedure is not visible from the
task level.
•
Must be in a loaded module, not installed. (Check the system parameter
Installed
in the type
Automatic Loading of Modules
in the
Controller
topic.)
Operating manual - OmniCore
161
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
6 Programming and testing
6.10.1 Running a service routine
Continued