4.3 Positioner Interface IRBP C
General
This section describes the I/O configuration for positioner IRBP C
I/O board Configuration for positioner
Re-
lay/Out-
put
Ana-
log/Out-
put
Ana-
log/In-
put
Digit-
al/Out-
put
Digit-
al/Input
Type
Name
Address
Simulated digit-
al I/O
B_POS_SIM
-
-
-
-
12
7
Digital I/O
DRIVO_1
1
Internal
bus
1) The number relates to the drive module where the I/O board is located, the
example shows DM1.
Simulated outputs for B_POS_SIM
Simulated outputs
Description
Name
UnitMap
Activate mechanical unit 1
soACT_INTCH
0
Simulated inputs
Description
Name
UnitMap
Mechanical unit 1 activated
siINTCH_ACT
0
I/O-Signals configuration for DRIVO_1
Digital outputs TB4
Connected to
unit
Description
Name
UnitMap
Output
0
1
1
2
2
3
3
4
Positioner
Activate mechanical unit 1
doACT_K5
4
5
5
6
6
7
7
8
8
9
Positioner
Activate release break 1
doACT_K15
9
10
10
11
11
12
0 V Output
13
Continues on next page
Product manual - IRBP /D2009
155
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
4 Configuration
4.3 Positioner Interface IRBP C
Содержание IRBP
Страница 1: ...ROBOTICS Product manual IRBP D2009 ...
Страница 2: ...Trace back information Workspace 20A version a6 Checked in 2020 03 05 Skribenta version 5 3 033 ...
Страница 38: ...This page is intentionally left blank ...
Страница 70: ...This page is intentionally left blank ...
Страница 250: ...This page is intentionally left blank ...
Страница 264: ...This page is intentionally left blank ...
Страница 314: ...This page is intentionally left blank ...
Страница 330: ...This page is intentionally left blank ...
Страница 333: ......