3.6.2 Electrical assembly IRBP
Connections
Positioner types A/B/C/D/K/R
Connection of the signals/media is made through the connection flanges.
Note
Action
3
2
1
3
xx1800003051
Electrical signals
1
Ground connection, weld
negative
2
Air connection (4 pcs)
3
Connect the electrical signals (1).
Suitable plugs are supplied for fitting on the incom-
ing cables. See
Circuit diagram
.
1
Connect the ground connection (weld negative,
(2)). The positioner chassis is to be separated
from the system ground; eg cable screen.
2
Connect the air (3) to the connections.
3
On the rotary unit, there is a free cable/hose for
connection to the fixture.
4
Current collectors
xx0900000990
Current collector connection 1
1
Current collector connection 2
2
Continues on next page
116
Product manual - IRBP /D2009
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
3 Installation and commissioning