5. Connect these cables:
•
DC+ cable (A) to the connector bolt (F1).
•
DC- cable (B) to the connector bolt (G1).
6. If you need to connect more DC cables, do steps 4 and 5 again for the other
wires and connector bolts (F2) and (G2).
7. Install the nuts and washers on the connector bolts of the DC busbars.
8. Tighten the nuts to the correct torque. For the specification, refer to section
8.4
Connect the AC auxiliary power cable
Preliminary requirements
•
Wire cutter
•
Wire stripper pliers
•
Torque screwdriver, cross
•
Crimp pliers
•
•
AC auxiliary power cable
•
Ferrules
Note: The AC auxiliary power cable provides the control power to the
charge post.
Procedure
1. Strip the insulation from the ends of
the wires (A) to (D). For the
specification, refer to section
2. Crimp ferrules onto the end of the
wires.
3. Loosen the screws of the terminals (E)
to (H) of the terminal block X-10.
4. Connect these wires:
•
PE wire (A), green/yellow, to the
terminal X10-1 (E)
•
L1 wire (B), brown, to the terminal
X10-2 (F)
•
L2 wire (C), black, to the terminal
X10-3 (G)
•
L3 wire (D), grey, to the terminal X10-4 (H)
5. Tighten the screws to the correct torque. For the specification, refer to section