L2234
Emax
127/158
Model
Scale
Page No.
Doc. No.
Apparatus
1SDH000460R0002
L2778
16.2 SD-Pocket
SD-Pocket is a software application designed to connect the new releases to a handheld (PDA) or laptop PC to use wireless communication for
communicating with the PR121/P, PR122/P and PR123/P specifically for:
- configuring the protection thresholds (PR122/P - PR123/P)
- viewing the measurements for the PR121/PR122/PR123 releases
- viewing the data saved in the recorder (Data Logger) of PR122/PR123 releases
- checking the conditions of the circuit-breaker (e.g., status, number of maneuvers, fault data, etc., depending on the release in question).
The scenarios for using SD-Pocket include:
- during commissioning, for a rapid and error-free transfer of the protection settings to the releases (also using the files for exchanging data directly
from Docwin)
- during the normal operation of the equipment, for collecting information on the circuit-breakers and the related loads (fault data, currents
measured and other data).
SD-Pocket requires a PDA with MS Windows Mobile 2003 and a Bluetooth interface, or a PC with MS Windows 2000 OS. The releases must
be complete with a PR120/D-BT or BT030 Bluetooth interface. It is not necessary, however, to have a PR120/D-M communication module.
SD-Pocket is distributed free of charge (freeware) and can be downloaded from the BOL site (http://bol.it.abb.com).
16.3 SD-Testbus2
SD-TestBus2 is the installation and diagnostic software for ABB SACE products with a Modbus RTU communication. It can be used during
commissioning, or to find faults in an already up and running communication network.
This enables the connection to a PR121/P, PR122/P and PR123/P.
SD-TestBus2 runs an automatic scan on the RS-485 bus, recording all the devices connected and checking their configurations, and also testing
all the possible combinations of addresses, parity and baud rate.
With a simple click on SCAN you can pinpoint the devices that fail to respond, the configuration errors, the wrong addresses and parity errors,
and so on.
After scanning, the software shows warning messages on potential problems or configuration errors, enabling a complete diagnosis of the
communication network. These functions are not limited to the ABB SACE devices: any apparatus using the Modbus RTU standard protocol is
recorded and tested.
For the ABB SACE circuit-breakers with an electronic release, the software provides a vast range of additional functions, for checking the wiring,
setting opening, closing or reset commands, and reading diagnostic information.
This program is so easy to use that it guarantees a trouble-free installation and commissioning of a Modbus communication network.
SD-TestBus2 is distributed free of charge (freeware) and can be downloaded from the BOL site (http://bol.it.abb.com).