Note:
Only frames R0…R5 need CPTC-02 to be supplied by an
external power supply, frames R6…R9 have corresponding terminals
40 and 41 on the control unit.
Description
Marking
External 24 V (AC/DC) input
24V AC/DC +
in
40
External 24 V (AC/DC) input
24V AC/DC - in
41
PTC sensor input
For the recommended cable type and correct tightening torque, see
the technical data.
To enable the SMT function, connect the PTC sensor to the PTC IN
input.
To disable the SMT function, connect a resistor (100 ohm … 1 kohm
¼ W wire-wound) to the PTC IN input.
Note:
If you do not connect a PTC sensor or resistor to the PTC IN
input, the STO function stays active. You cannot start the motor while
the STO function is active.
Wiring examples
Connect the external control cables to the applicable module
terminals. Ground the outer shield of the cables 360 degrees under
a grounding clamp on the grounding shelf of the control cables.