WARNING!
Make sure that the drive is disconnected from the input power
during installation. Before you start the work, stop the drive
and do the steps in section
.
Necessary tools and instructions
• Screwdriver with a set of suitable bits
• Cabling tools
Selecting the location for the drive
Install the drive, the CPTC-02 module, and the STO circuit outside
any potentially explosive atmosphere. Consider the ambient conditions
specification in the drive hardware manual.
General wiring instructions
1. For the STO circuit wiring, use the type of cable specified in the
applicable drive hardware manual.
2. Install only the sensor circuit into the potentially explosive
atmosphere.
The sensor circuit in the Ex Zone must comply with the
requirements for the applicable type of protection, such as:
• Ex d (IEC/EN 60079-1)
• Ex eb (IEC/EN 60079-7, Ex e in EN 60079-7:2007 and IEC
60079-7:2006)
• Ex ec (IEC/EN 60079-7, Ex nA in IEC/EN 60079-15:2010).
36 Electrical installation