Specification overview, internal controller
Specification
Item
Maximum 50 I/O devices
Number of I/O devices connected to control-
ler
Maximum 256 input bytes and 256 output
bytes per device.
Connection size
Specification overview, internal device
Specification
Item
See
GSDML file
2.33
PROFINET Version
Slot 1-2: Digital input or output modules of
variable size
Slot configuration
Maximum 256 input bytes and 256 output
bytes per device.
Connection size
Default gateway
There are multiple default gateways in the system. And hence, it is possible to
have two different default gateways in the system, one for the non-PROFINET
traffic and one that only manages the PROFINET interface and its traffic. So while
using option
PROFINET Controller/Device
the LAN 3 port is used only for PROFINET
traffic.
Link Layer Discovery Protocol (LLDP)
The IRC5 controller supports LLDP, but only on one port at a time. Preferrably
LLDP should be used on the PROFINET network. Any network connected to another
port must have LLDP disabled (or use equipment not supporting LLDP).
Factory Network
Not using LLDP
WAN
LAN 2
LAN 3
Robot Controller
LAN 1
Service
Private PROFINET network
Using LLDP
xx1800000140
Continues on next page
Application manual - PROFINET Controller/Device
17
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
1 Introduction
1.2 PROFINET for IRC5
Continued
Содержание 888-2
Страница 1: ...ROBOTICS Application manual PROFINET Controller Device ...
Страница 2: ...Trace back information Workspace R18 1 version a16 Checked in 2018 04 18 Skribenta version 5 2 025 ...
Страница 28: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 86: ......
Страница 87: ......