C Using PROFINET Configurator Express
Creating controller network configuration file using PROFINET Configurator Express
Description
The following example is performed using
PROFINET Configurator Express
.
This example demonstrates how to create a PROFINET configuration file for one
device, a Siemens ET200S with 5 DO 2-bit modules and 1 DI 2-bit module.
Action
Start PROFINET-IO Configurator Express.
1
In PROFINET-IO Configurator Express, click
File
and select
New
to create a new
empty project.
2
Click
File
and select
Save
to save the new project. Use the name "TestProject".
3
In the
Bus Structure
window, make sure that the "TestProject" node is selected.
4
In the
Device Details
window, set the PROFINET IP range for this project by setting
the following parameters:
•
Last IP Address: 192.168.5.254
•
First IP Address: 192.168.5.2
•
Subnetmask: 255.255.255.0
en1100000063
5
In the
Device Catalog
window, expand the nodes
Phoenix Contact Software GmbH
,
Generic PN
and
PLC
.
•
Select the PLC version that corresponds to the current version of the
Phoenix
Contact Software
. Currently, it is 3.9 version.
xx1400002205
6
Continues on next page
Application manual - PROFINET Controller/Device
79
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
C Using PROFINET Configurator Express
Содержание 888-2
Страница 1: ...ROBOTICS Application manual PROFINET Controller Device ...
Страница 2: ...Trace back information Workspace R18 1 version a16 Checked in 2018 04 18 Skribenta version 5 2 025 ...
Страница 28: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 86: ......
Страница 87: ......