One PROFINET network connected to the robot controller
If PROFINET is used on the public network (WAN port) without an Anybus adapter,
PROFINET cannot be used on the private network. Equipment not using PROFINET
(for example a camera) can be connected to the private network. To use PROFINET
on both the public and private network, an Anybus adapter must be used. See
Using Anybus adapter to connect two PROFINET networks on page 24
PROFINET on factory network
When the WAN port is used for connecting to an industrial network, the traffic
shares the same media as the factory network and will share bandwidth with other
non industrial network traffic.
The following figure illustrates the network when connecting a controller and a
device to the WAN port of the main computer:
WAN
LAN 2
LAN 3
Private
LAN 1
Service
Public
WAN
Factory Network & Industrial Network
LAN 2
LAN 3
Private
Robot Controller 1
LAN 1
Service
Robot Controller 2
PLC
Camera
Public
Cell I/O
I/O
I/O
PROFINET
xx1500000472
Continues on next page
Application manual - PROFINET Controller/Device
21
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
2 Hardware overview
2.1 Main computer
Continued
Содержание 888-2
Страница 1: ...ROBOTICS Application manual PROFINET Controller Device ...
Страница 2: ...Trace back information Workspace R18 1 version a16 Checked in 2018 04 18 Skribenta version 5 2 025 ...
Страница 28: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 74: ...This page is intentionally left blank ...
Страница 78: ...This page is intentionally left blank ...
Страница 86: ......
Страница 87: ......