364xS User’s Manual
43
Operation
Display indication
Description
Level
Type
Set Display LRV (0%)
Set the display to show 0% at the defined Lower
Range Limit
Utility
Numerical
Set Display URV (100%)
Set the display to show 100% at the defined Upper
Range Limit
Utility
Numerical
Display Transfer Func
Set the display transfer function (indipendent from
the output transfer function)
Utility
Enumerated
Security
This function set the security features
Sub Sub
Menu
Display Protection
Set the protection or remove the protection
Utility
ASCII String
Change Password
Modify the password
Utility
ASCII String
Totalizer
This function provides all the totalizer settings
Main Menu
Totalizer status
Set the totalizer status
Utility
Enumerated
Reset
Reset the totalizer value
Sub Menu
Permanent Totalizer
This function provides the setting of the
permanent totalizer
Sub Sub
Menu
Reset
Reset the permanent totalizer
Utility
Auto Adjust
Tot. Protection
Set the permanent totalizer protection
Utility
ASCII String
Change Password
Modify the permanent totalizer password
Utility
ASCII String
Batch Totalizer
Set the batch totalizer parameter
Utility
Auto Adjust
Totalizer Settings
This function provides the totalizer setting
Sub Menu
Totalizer LRV (0%)
Set the Totalizer Lower Range Value
Utility
Numerical
Totalizer URV (100%)
Set the Totalizer Upper Range Value
Utility
Numerical
Input Eng. Units
Set the Totalizer engineering unit
Utility
Enumerated
Permanent Eng. Unit
This function provides the Permanent Totalizer
engineering unit
Sub Sub
Menu
Engineering Unit
Set the Permanent Totalizer engineering unit
among a predifined list
Utility
Enumerated
Custom Unit
Set the Permanent Totalizer engineering unit in the
custom version
Utility
ASCII String
Conversion Factor
Set the Permanent Totalizer Conversion Factor
Utility
Numerical
Batch Eng. Unit
This function provides the Batch Totalizer
engineering unit
Sub Sub
Menu
Engineering Unit
Set the Batch Totalizer engineering unit using a
predefined list
Utility
Enumerated
Custom Unit
Set the Batch Totalizer engineering unit in the
custom version
Utility
ASCII String
Conversion Factor
Set the Batch Totalizer Conversion Factor
Utility
Numerical
Bidirectional Flow
Defines the sum or the subtraction of the positive
and negative flow (the bidirectional transfer
function has to be selected)
Utility
Enumerated
Communication
This function provides all the Communication
settings
Main Menu
HART Tag
Set the Tag value in the transmitter database
Utility
ASCII String
Descriptor
Set the Descriptor value in the transmitter
database
Utility
ASCII String
Message
Set the Message value in the transmitter database
Utility
ASCII String
Polling Address
Set the Polling Address value in the transmitter
database
Utility
Enumerated
Содержание 2600T Pressure Transmitter Series
Страница 1: ...InstrumentationIT 2600T Pressure Transmitter family ABB User s Manual 364DS and 364PS Models ...
Страница 7: ...364xS User s Manual 7 This page has been intentionally left blank ...
Страница 72: ...364xS User s Manual 72 Additional Safety ...
Страница 74: ...364xS User s Manual 74 Additional Safety ...
Страница 75: ...364xS User s Manual 75 Digital LCD Display Keys sequences Annex I Digital LCD Integral Display Menu Flow Chart ...