gle “Panic” button or by the simultaneous operation of two buttons. The
Fire and Medical alarms are generated by pressing two buttons simultane-
ously.
There are two types of LCD keypad that can be used on the panel. The
methods for generating these manual alarms vary depending on the key-
pad used.
The special button combinations and the alarms they generate are shown
in the table below;
RESETTING ALARMS
In case of an alarm condition,
pressing your
<CODE>
then
<ENTER>
will reset the alarm and turn off any audible sirens. If your code does not
reset the alarm it means that the alarm occurred in an Area either not as-
signed to the keypad you are using or your code is not allowed to reset
alarms in that area.
NOTE:
If at any stage you make an error when entering a code all you
need to do is press the
<ENTER>
button to reset the keypad and start
again.
LCD KEYPAD QUICKVIEW MODE
The LCD keypad will normally show an unsealed zone by displaying its
programmable zone name on the keypad. If more than one zone is un-
sealed at any time the LCD keypad will scroll through the zones sequen-
tially showing each zone name individually. This can take some time to
display all zones if multiple zones are unsealed. The LCD keypad has a
KEYPAD
TYPE
È
PANIC ALARM
FIRE ALARM MEDICAL ALARM
LED
KEYPAD
<PANIC>
<1> & <3>
<4> & <6>
<7> & <9>
CROW LCD
KEYPAD
<CHIME> & <CONTROL>
<A> & <B>
<B> & <CHIME>
AAP LCD
KEYPAD
<PANIC>
<1> & <3>
<4> & <6>
<7> & <9>