Страница 1: ...1 OperatingGuide ...

Страница 2: ...2 ...

Страница 3: ...3 ...

Страница 4: ... Local Command Control of outputs 14 Remotely Acknowledging an Alarm 15 PROGRAMMING YOUR ALARM 16 Getting into Program Mode 16 Exiting Program Mode 16 Adding or Deleting User Codes 16 Changing Telephone Numbers 17 Programming the Time Date 18 Programming DTMF Control Code 18 Program Delete Find Radio Users 19 Program Delete Find Access Tag Card Users 19 Program Delete Find Radio Zones 20 Hide User...

Страница 5: ...le area or both areas depending on what Areas are assigned to the keypad or code or both The installer will advise you on how they have configured your particular alarm There is also a special feature that can be set by your installer to allow the pressing of the ARM button during the Exit Delay time to Disarm the alarm This feature is to allow a quick disarm if you have forgotten to do something ...

Страница 6: ...isarming the alarm will turn off all detectors in the Area or Areas that were Armed To Disarm the alarm press CODE ENTER Area A B or both armed LED s will turn OFF Only the Areas assigned to the user code and keypad will disarm To allow disarming of both areas the keypad and the user code must be assigned to Areas A B For example if the keypad was assigned to both areas but the code was only assig...

Страница 7: ...oceed to automatically disarm both areas in 10 seconds time ARMING IN STAY MODE Stay mode allows you to Arm a pre selected part of the building Stay mode can be used in a residential application to arm parts of the house that you will not need to go into at night time or in a commercial application to allow monitoring of an unattended shop front The Stay mode alarm can be in the form of a full ala...

Страница 8: ...grammable option selectable at individual keypads so you will need to check with your installer how your system has been configured Disarming using the Stay button can be programmed not to work if the panel is in alarm If the button is programmed this way when in alarm you must use your code to disarm If the panel is programmed for Stay Code Enter for arming stay mode and the code and keypad are a...

Страница 9: ...ts 01 the display will show 01 then if you enter 09 the display will show 01 09 on the display and finally as you enter 16 the display will show all three numbers on the screen The LCD keypad will show up to 5 two digit num bers then if you need to bypass more zones it will alternate the display with the first 5 selections then the next 5 switching between displays at about a 1 second rate The ins...

Страница 10: ...ed in an Area either not as signed to the keypad you are using or your code is not allowed to reset alarms in that area NOTE If at any stage you make an error when entering a code all you need to do is press the ENTER button to reset the keypad and start again LCD KEYPAD QUICKVIEW MODE The LCD keypad will normally show an unsealed zone by displaying its programmable zone name on the keypad If more...

Страница 11: ...n be used to disable Chime zone alarms or directly control any of the outputs from the keypad The operation of the special CONTROL button functions if enabled by the installer are detailed below DIRECTLY CONTROLLING an OUTPUT To directly control outputs from the LED or LCD keypads press CONTROL Note The Control Button must be held for 2 seconds The control LED will turn on at the LED keypad the LC...

Страница 12: ...display or you can press the ENTER button to go back to the normal display To re enable Chime Zone monitoring press and hold CONTROL followed by PROGRAM The Aux 0 LED will turn off indicating the Chime Zones are now active on the LED keypad or the words CHIME ON will appear briefly on the LCD keypad The Display will timeout after 20 seconds back to the normal display or you can press the ENTER but...

Страница 13: ... phone number and the panel answers the call the first thing you will hear over the phone is a burst of modem tones for two seconds The panel will then pause for a period of 5 seconds and listen for DTMF tones from the remote phone During the pause you must enter the access code which is associated with the Com mand menu option you wish to access Remember the code you enter will determine which me...

Страница 14: ...urn on the optional Microphone only available if the Voice Board is fitted you must enter in the appropriate code followed by the button To turn the Microphone off you simply press the button again To end a Command Control session simply hang up the phone The panel is monitoring the line at all times and 15 seconds after the last key press it will automatically hang up the line This 15 second time...

Страница 15: ... and then waiting for a period of 5 seconds for an alarm acknowledgement If no acknowledgement was received the panel will repeat the message and wait a further 5 seconds This pattern is repeated 4 times and if no acknowledgement was received the panel will hang up and dial the next number if more than one was programmed To acknowledge the alarm you must press the button on your tele phone during ...

Страница 16: ...e things can be explained in detail by your installer To get into CLIENT mode provided the system is NOT armed press PROGRAM CODE ENTER The Program LED with turn ON LED keypad or The LCD Keypad will display CLIENT USERS If you get a single long beep at this point and the above indications do not happen it means your code cannot access Program mode EXITING PROGRAM MODE To exit out of program mode p...

Страница 17: ...NE NUMBERS Your panel will accept up to 8 phone numbers with a total of 16 digits It can be can be programmed to dial all or any of these depending on the event which has occurred The 8 phone numbers are at program addresses P181E 1 8E While in CLIENT mode key in the following sequence PROGRAM 181 ENTER 1 ENTER the address for telephone number 1 Any existing number will be displayed at the keypad ...

Страница 18: ...o 7 Sat PROGRAM 26 ENTER 3 ENTER DDMMYY ENTER DDMMYY date month year To view or set daylight saving On PROGRAM 26 ENTER 4 ENTER If LED 1 is on daylight saving is currently active To Program Holidays PROGRAM 170 ENTER 1 8 ENTER DDMMYY ENTER Where 1 8 relates to holidays 1 8 and DDMMYY date month year PROGRAMMING THE DTMF REMOTE CONTROL CODES The alarm system has the ability to allow the owner to ca...

Страница 19: ...or cards programmed at user locations 1 100 There must be at least one proximity reader connected to the panel for access tags cards to work The owner can add remove or find radio users or access tags from CLIENT program mode To Learn a new Radio User press PROGRAM 18 ENTER 21 100 ENTER 21 100 is User number 21 100 When in learn mode the keypad will beep at one second intervals for 30 seconds You ...

Страница 20: ...MMING DELETING or FINDING RADIO ZONE CODES The alarm system can have up to 16 radio detectors zones programmed provided a receiver is fitted to the panel Any of the 16 zones can be wired or wireless zones The owner can add remove or find radio zones from CLIENT program mode To Learn a new Radio Detector zone press PROGRAM 164 ENTER 1 16 ENTER 1 16 is Zone 1 16 When in learn mode the keypad will be...

Страница 21: ...er Codes from CLIENT program mode To Hide User Codes press PROGRAM 25 ENTER 12 ENTER then 1 ENTER If option 1 is turned ON at location P25E12E the installer cannot view User Codes when in Installer Mode To allow the installer to view and pro gram codes the user must turn option 1 OFF at this location Location P25E12E can ONLY be accessed from Client Mode by an authorised user ...

Страница 22: ... return to the key pad and all of the zones that were triggered will be displayed at the key pad To terminate Walk test mode press ENTER The keypad will stop beeping and automatically exit CLIENT mode ANSWER AN IN COMING CALL From time to time your installer may need to access the alarm from a re mote PC to make changes to your programming and for security reasons they may have configured the alar...

Страница 23: ... program mode To Force a Test Call from the keypad press CONTROL 0 You must hold the control button down and press 0 within 2 seconds The alarm Panel will now call the monitoring company and send a manual test call event type 601 To Force a Test Call from a remote telephone dial the panel When the panel answers the call it will send the modem tones When the tones finish enter in the Remote Test Co...

Страница 24: ...vents in text form with full descriptions of the alarm condition as well as time and date informa tion The LCD keypad needs no explanation when it comes to displaying memory events because they are shown in plain text The second is an LED keypad that uses LED s to indicate the alarm condi tions There is also two different types of LED keypads the standard LED key pad and the OEM icon LED keypad Th...

Страница 25: ...o refer to the keypad refer ence drawing on page 30 for the equivalent symbols on the OEM LED keypad The other main difference between the standard LED keypad and the OEM LED keypad is the operation of the MAINS AC Fail and BATTERY Battery Low LED s On the standard LED keypad the LED s are always illuminated and they flash when there is a problem but the mains and battery symbols on the OEM LED ke...

Страница 26: ...hing Flashing SUPERVISED RADIO TIMEOUT Zone 1 16 LED s 1 16 TROUBLE BYPASS On Steady Flashing Flashing LED KEYPAD HISTORICAL EVENT DISPLAY CHART EVENT DEVICE INDICATOR STATUS ACTIVATION Zones 1 16 LED s 1 16 On Steady BYPASS Zones 1 16 BYPASS LED s 1 16 On Steady On Steady DETECTOR TAMPER SHORT CIRCUIT Zones 1 8 TROUBLE LED s 1 8 Flashing On Steady DETECTOR TAMPER OPEN CIRCUIT Zones 9 16 TROUBLE L...

Страница 27: ...9 16 Flashing On Steady KEYPAD FIRE Fire Alarm at Keypad LINE CONTROL LED s 1 8 Flashing Flashing On Steady KEYPAD MEDICAL Medical Alarm at Keypad LINE BYPASS LED s 1 8 Flashing Flashing On Steady ARMED Area A Armed A On Steady ARMED Area B Armed B On Steady STAY MODE ON Area A in Stay Mode A Flashing STAY MODE ON Area B in Stay Mode B Flashing TELEPHONE LINE FAIL Panel Dialler LINE On Steady EXCE...

Страница 28: ...turday P26E3E DDMMYY Real time clock Date Month Year P26E4E Daylight saving active If 1 is On daylight saving is active P27E1E 0 5E Daylight saving start Sunday P27E2E 0 5E Daylight saving end Sunday P28E1E 1 12E Daylight saving start Month P28E2E 1 12E Daylight saving end Month P29E1E 0 23E Daylight saving start Hour P29E2E 0 23E Daylight saving end Hour P63E 1 2E E Area A 1 or B 2 DTMF arm disar...

Страница 29: ...st calls will interrupt any other calls that may be set up on the line at the same time The timing set for such test calls should be discussed with the installer 4 The timing set for test calls from this equipment may be subject to drift If this proves to be inconvenient and your calls are interrupted then the problem of timing should be discussed with the equipment installer The matter should NOT...

Страница 30: ...3 Code 4 Code 5 Code 6 Code 7 Code 8 Code 9 Code 10 Code 11 Code 12 Code 13 Code 14 Code 15 Code 16 Code 17 Code 18 Code 19 Code 20 Code 21 PANEL TELEPHONE NUMBERS PH 1 PH 2 PH 3 PH 4 PH 5 PH 6 ZONE DESCRIPTIONS Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 ...