background image

 

AD4329A-DLC 

Page 4 

1. Introduction 

AD4329A-DLC is a digital load cell weighing indicator that enables use of truck scales. 

By combining the AD4329A-DLC with an A&D digital load cells (LCCD20 series), a weighing system with higher 

lightning resistance performance can be built, and electronic corner adjustment can be performed easily and 

precisely. Up to eight digital load cells can be connected in parallel. 

AD4329-DLC's interface has standard serial output to enable connection to A&D printers and displays and RS-

232C to enable connection to PCs. In addition, comparator relay output can be provided as an option. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание AD4329A-DLC

Страница 1: ...AD4329A DLC Weighing Indicator INSTRUCTION MANUAL 1WMPD4003952...

Страница 2: ...bration 15 6 1 Scale interval setting 17 6 2 Maximum capacity setting 17 6 3 Zero compensation at four corner adjustment 18 6 4 Adjustment weight at four corner adjustment 18 6 5 Four corner adjustmen...

Страница 3: ...ng the multi interval settings 50 12 9 3 Confirming the linearity calibration 50 12 9 4 Confirming the gravitational acceleration compensation 1 50 12 9 5 Confirming the gravitational acceleration com...

Страница 4: ...ng system with higher lightning resistance performance can be built and electronic corner adjustment can be performed easily and precisely Up to eight digital load cells can be connected in parallel A...

Страница 5: ...with oil chemicals or water Please note that securing the indicator to the control panel will provide the indicator outside of the control panel with IP65 protection When installing or removing the i...

Страница 6: ...of the minimum division 4 Key switch with sealingcover CAL key Switches to calibration mode OPR STB key Turns the display on off Preset tare key Displays the preset tare value M key Adds the current...

Страница 7: ...Fuse holder 4 External control input connector 5 Standard serial output connector 6 RS 232C I F connector 7 Option 02 comparator output slot 2 3 Accessories Name Qty Instruction Manual 1 Connector for...

Страница 8: ...ion 1 AC power input Live Unearthed conductive part 2 AC power input Neutral Earthed conductive part 3 Ground terminal The test below is performed for lightning resistance performance of the AD4329A D...

Страница 9: ...Load cell input terminal assignment Use an M3 solderless terminal with a width of 6 2 mm or less Terminal No Symbol Description 4 SHILD Shield 5 POW Load cell excitation voltage 6 POW Load cell excit...

Страница 10: ...connect the digital load cells in parallel use a junction box for digital load cells Connecting the weighing indicator to four digital load cells is as shown below Recommended cable is AX KO3217 A D...

Страница 11: ...furthest from the weighing indicator as is and cut the jumpers JP1 in the other junction boxes using wire cutters Fig 4 shown below is an example connection diagram when using an AD4388 4 and an AD43...

Страница 12: ...F function mode f 01 Press CAL to go to CF function mode Select Cf 100 by the following key operations ZERO Move the flashing digit TARE Change the value of the flashing digit PRINT Confirm the displ...

Страница 13: ...n setting the serial number set it in the order for corner adjustment starting from Cf 101 Check the serial number marked on each digital load cell For example with the LCCD20 series manufactured by A...

Страница 14: ...the following key operations ZERO Move the flashing digit TARE Change the value of the flashing digit PRINT Update to the new value and return to the item selection MODE Cancel the value setting and...

Страница 15: ...the following items required for calibration Scale interval resolution setting Maximum capacity setting Four corner adjustment Zero calibration Span calibration Linearity calibration if necessary Gra...

Страница 16: ...e interval setting d 01 C 10000 Cal 0 f 10000 Maximum capacity setting Zero calibration Span calibration 4C Cal0 g1 9798 Cap2 02 lnr 1 Linearity calibration Multi interval function Gravitational accel...

Страница 17: ...to the next item MODE Skip this item and go to the next item 6 2 Maximum capacity setting Set a maximum capacity by the following key operations TARE Change the value of the flashing digit ZERO Move...

Страница 18: ...adjustment and go to the next item 6 4 Adjustment weight at four corner adjustment Press PRINT Set an adjustment weight value for corner adjustment by the following key operations TARE Change the val...

Страница 19: ...rner adjustment for 1st digital load cell Press PRINT Put the adjustment weight on the 2nd digital load cell When the MD mark illuminates press PRINT to execute corner adjustment for 2st digital load...

Страница 20: ...he flashing digit ZERO Move the flashing digit MODE Skip span calibration and return to scale interval setting Place the calibration weight on the scale When the MD mark illuminates press PRINT to exe...

Страница 21: ...g 1st range Interval 0 01kg is selected When the weighing value is between 20 and 50kg 2nd range Interval 0 02kg is selected Display When the weighing value is between 50 and 100kg 3rd range Interval...

Страница 22: ...000 C 20000 Scale interval setting for 1st range 1 Cal 0 Zero calibration 1 Press TARE within 2 seconds after d XX appears in the display and the scale interval setting for the 2nd or 3rd range will a...

Страница 23: ...point Set the following items to adjust linearity Calibration for compensation point 1 Calibration for compensation point 2 If necessary Calibration for compensation point 3 If necessary Before compe...

Страница 24: ...ight by the following key operations TARE Change the value of the flashing digit ZERO Move the flashing digit MODE Delete compensation point 2 and 3 to go to span calibration Place the adjustment weig...

Страница 25: ...ing Set the gravitational acceleration for the calibration location by the following key operations The decimal point is not displayed TARE Change the value of the flashing digit ZERO Move the flashin...

Страница 26: ...hing range is larger than the next weighing range err 13 Shows that the adjustment weight settings for linearity adjustment don t meet the following conditions The weight setting for lnr 1 The weight...

Страница 27: ...lay in weighing mode are as follows Weighing value Positive overload Negative overload Error display Description errAd n The n th digital load cell has a problem in the internal circuit errlC n The n...

Страница 28: ...set to zero automatically when the gross value meets the zero tracking condition F 01 7 6 Power on zero After turning on the power the gross value is set to zero automatically when the gross value is...

Страница 29: ...ue is set to 0 by the following operations Turn off power Pressing TARE when the gross value is 0d Power on zero Push zero 7 10 Preset tare This subtracts a preset tare from the gross value If you use...

Страница 30: ...d 3 20d 4 50d Accumulation execution Manual accumulation When M is pressed with the MD mark illuminated accumulation is executed and the display flashes once Auto accumulation When the MD mark is illu...

Страница 31: ...Press MODE 2 After total is displayed the total value is displayed with M mark flashing 3 Press and hold ZERO for 3 seconds or longer 4 After the display flashes once the total value is cleared to 0...

Страница 32: ...nufactured by Hosiden is included as an accessory If you use external control inputs select the functions for each pin from the following settings 0 None default 1 ZERO key 2 TARE key 3 PRINT key 4 OP...

Страница 33: ...6 715267 connector manufactured by Hosiden is included as an accessory Pin No Description 1 NC 2 NC 3 Current loop output no polarity 4 NC 5 Current loop output no polarity 6 NC 7 NC Shell Frame groun...

Страница 34: ...If you connect a printer without receive buffer set the data interval F 33 to 1 2 seconds Select communication mode F 31 from the following settings 0 Stream default Weighing data is output at the di...

Страница 35: ...34 5 Numerical value with polarity 0000000 0 SP SP SP SP SP SP Positive overload Weighing data 1 SP SP SP SP SP SP Negative overload kg Kiro gram Unit CF 001 1 SP t Ton 1 It is possible to select the...

Страница 36: ...times If you use the comparator output set the following settings Set comparator function F 20 to 1 Enable Default is 0 Disable Select comparator function inhibition condition F 21 from the following...

Страница 37: ...ing digit NET GROSS Switch the polarity PRINT Update the value MODE Skip the upper limit value lo will appear on the display for 2 seconds Change the lower limit value by the following key operations...

Страница 38: ...panel with the main board 3 Remove two M3 screws on the COMP OUT slot and the blank panel 4 Install the comparator output option to the rear panel with two M3 screws 5 Connect the 5 wire cable between...

Страница 39: ...h screws The connector is not provided and must be prepared by the user Pin No Description 1 NC 2 TXD output 3 RXD input 4 NC 5 SG 6 9 NC Communication specifications Signal level RS 232 Baud rate F 4...

Страница 40: ...3 to 1 2 seconds Select communication mode F 41 from the following settings 0 Stream default Weighing data is output at the display update rate 1 Auto print When the MD mark is illuminated a weighing...

Страница 41: ...0000 0 0 SP SP SP SP SP SP Positive overload Weighing data 1 SP SP SP SP SP SP Negative overload kg Kilograms Unit CF 001 1 SP t Ton 1 it is possible to select the number of digits and decimal point f...

Страница 42: ...ross value MN CR LF Switch the display to net value When transmitting the following command and writing data is sent the data will be updated and the command and writing data will be echoed back PT 21...

Страница 43: ...CHc1 o U t CHc r 5 CHc f CHc1 C f CHc1 C a l Off mode Weighing mode init Confirmation of the digital load cell Confirmation of the keys Confirmation of the standard serial output Initialization Confir...

Страница 44: ...splaying lC4 5n for 2 seconds the serial number is displayed After displaying lC4 Cap for 2 seconds the maximum capacity is displayed After displaying lC4load for 2 seconds the actual load applied to...

Страница 45: ...4329A DLC Page 45 12 2 Confirming the keys Press the each key to switch the corresponding o to 1 oooooo 1ooooo o1oooo oo1ooo ooo1oo oooo1o ooooo1 ooo 1oo o1o oo1 2 seconds later CHc1yey 2 seconds late...

Страница 46: ...COM the corresponding o to switched to 1 12 4 Confirming the standard serial output Press PRINT to transmit ST G 00000 0kg CR LF Communication specifications depend on settings for F 30 to F 34 Cl Cl...

Страница 47: ...munication specifications depend on settings for F 40 to F 47 When receiving data the first four characters are displayed The example at the right is when A123 CR LF is received Communication specific...

Страница 48: ...splay the setting value for the currently displayed item 12 8 Confirming the CF function setting values Operate the following keys to select the items to be confirmed TARE Change the value of the flas...

Страница 49: ...val Multi interval settings Linearity calibration Gravitational acceleration compensation 1 Confirmation of each setting value Calf CalC Maximum capacity Gravitational acceleration compensation 2 Weig...

Страница 50: ...erval settings for 2 seconds 12 9 3 Confirming the linearity calibration Press PRINT to proceed to the next confirmation item after displaying the number of compensation points for linearity calibrati...

Страница 51: ...em after displaying the weight value at span calibration for 2 seconds 12 9 7 Confirming the load cell output at zero calibration Press PRINT to proceed to the next confirmation item after displaying...

Страница 52: ...to be confirmed TARE Change the load cell to be confirmed PRINT Return to previous display after displaying the compensation value for 2 seconds 12 9 11 Compensation value for four corner adjustments...

Страница 53: ...dition to the parameter Initialization of all data Initializes the calibration settings in addition to the parameter and function and sets the weighing indicator to the factory settings Follow the pro...

Страница 54: ...t TARE Change the value of the flashing digit PRINT Confirm the displayed item Change the value by the following key operations ZERO Move the flashing digit TARE Change the value of the flashing digit...

Страница 55: ...umulation mode and value polarity condition 0 1 2 3 Manual Only plus value Manual Both plus minus value Auto Only plus value Auto Both plus minus value 0 05 Accumulation inhibition range 0 1 2 3 4 0 d...

Страница 56: ...11 EXT2 Pin3 0 12 EXT3 Pin4 0 13 EXT4 Pin5 0 14 EXT5 Pin6 0 15 EXT6 Pin7 0 16 External control input function EXT7 Pin8 0 1 2 3 4 5 6 7 8 9 10 11 None ZERO key TARE key PRINT key OPR STB key M key NE...

Страница 57: ...d or less or unstable Displayed value is within 5d Displayed value is within 5d or is unstable 0 13 2 4 Standard serial output F Item Setting value Default User setting 30 Output data 0 1 2 3 4 Displa...

Страница 58: ...e value Gross Net Tare value 0 41 Communication mode 0 1 2 3 4 Stream Auto print Manual print Command Reserved 0 42 Auto print inhibition range 0 1 5 d or less Within 5 d 0 43 Data interval at F 40 4...

Страница 59: ...E Change the value of the flashing digit PRINT Confirm the displayed item Change the value by the following key operations ZERO Move the flashing digit TARE Change the value of the flashing digit PRIN...

Страница 60: ...ero 0 1 Disable Enable 1 006 Execution Preset tare 0 1 Enable Disable 1 007 When outputting the net value the preset tare value is output as well 0 1 Disable Enable 1 008 Output on over load and unsta...

Страница 61: ...61 CF Item Setting value Default User setting 100 Number of digital load cells 1 to 8 4 101 1st 102 2nd 103 3rd 104 4th 105 5th 106 6th 107 7th 108 Serial number of each digital load cell 8th 0000000...

Страница 62: ...ge 62 14 Check the Software Version Press OPR STB While pressing and holding MODE press OPR STB Press MODE The software version will appear Press OPR STB twice to back to weighing mode 0 00 f 0 1 OPR...

Страница 63: ...to eight A D digital load cells can be connected in parallel Sampling rate 10 times s Display Weight display 7 digit LED with character height of 13 mm Units kg t selectable Status lamp M MD GROSS NE...

Страница 64: ...AD4329A DLC Page 64 External Dimensions Unit mm Panel cut dimensions Panel thickness 1 6 to 3 2...

Страница 65: ...44 1235 550485 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bldg 33 Gukjege...

Отзывы: