AD4329A-DLC
Page 55
13.2. F-function list
13.2.1. Basic weighing function
F-
Item
Setting value
Default User
setting
01 Zero
tracking
condition
0:
1:
6:
7:
Not used
0.5 d / 1.0 s
0.5 d / 2.0 s
1.0 d / 2.0 s
7
02
Stability detection condition
Push zero and tare only at stable weight.
6:
7:
0.5 d / 2.0 s
1.0 d / 2.0 s
6
03
Display update rate
0:
1:
10 times/s
5 times/s
0
04
Operations at accumulation mode and value
polarity condition
0:
1:
2:
3:
Manual / Only plus value
Manual / Both plus/minus value
Auto / Only plus value
Auto / Both plus/minus value
0
05
Accumulation inhibition range
0:
1:
2:
3:
4:
0 d
5 d
10 d
20 d
50 d
1
X
0:
1:
06
Key lock in weighing mode
Select a target key by [ZERO] key.
Select 0: unlock / 1: lock by [TARE] key.
If you lock [OPR/STB], turn on the power
while pressing and holding [OPR/STB] and
[MODE] to go to F-function mode.
X
1:
2:
3:
4:
5:
6:
7:
8:
Unlock
Lock
[OPR/STB] key
[PRESET TARE] key
[M+] key
[MODE] key
[NET/GROSS] key
[ZERO] key
[TARE] key
[PRINT] key
10
20
30
40
50
60
70
80