82
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
To
talizers
Sets and controls action of
the flow T
o
talizers.
NOTE: Start T
o
talizer at
Flow value must be entered
for in %FS (0.0 – 100.0).
Limit volume must be
entered in currently selected
EU. If T
o
talizer hit limit
event is not required, set
“Limit V
o
lume” value (argu-
ment 4) to zero. T
o
talizer#1
can be configured to Count
Up only (argument M is not
supported). T
o
talizer#2 can
be configured to Count Up
or Count Down mode.
When configured to Count
Down mode, limit volume
must be more than zero.
To
talizer#1 reading is stored
in EEPROM (non-volatile)
memor
y. Power cycle will
not affect T
o
talizer#1 read-
ing.T
otalizer#2 reading is
backed up in EEPROM with
6 minutes inter
val. Power
cycle may affect T
o
talizer#2
reading. T
o
talizer#1 cannot
be reset if ResetLock (EE
index 70) value set to 1.
11
T
1 (T
otalizer #1)
2 (T
otalizer #2)
Z
(Reset to zero)
T1Z or T2Z
C
Start flow and Event
Condition
<value>
(start T
o
talizer at flow)
%FS [0.0 – 100.0]
<value>
(Limit volume In current
volume based EU)
T1C:2.5, 0.0
or T2C:2.0,20580.5
P
Power On Delay
<value>
(0-3600 sec.)
T1P:10 or T2P:20
D (disable T
otalizer)*
T1:D or T2:D
E (enable T
o
talizer)
T1:E or T2:E
R (read current T
o
talizer
volume)
T1R:<value> or
T2R:<value> (in current EU)
S
(read current
settings status)
T1S:Mode,Direction,Start
Flow
,LimitV
olume,
PowOnDelay
,AutoResetMode,
AutoResetDelay Example:
T1S:E,0,0.5, 2045.2,10,0,5
A
Set Auto Reset/Reload
mode
<value> [0-1]
0 – Disable
1 – Enable
T1A:0 - disabled
Or T2A:1 - enabled
I
Set Auto Reset/Reload
Inter
val delay
<value>
[0-3600 sec.]
T1I:2 Or T2I:0
B
Restore T
o
talizer#1
value from EE backup
T1B
Not supported by T
o
talizer #2.
M
To
talizer#2 counting
direction configuration
<value> [0-1]
0- Count Up
1-Count Down
T1M:0
Not supported by T
o
talizer #1.
Содержание TIO
Страница 14: ...10 Figure 4 3 RS 485 Multidrop Half Duplex Two Wire System...
Страница 55: ...51 Figure 6 2 Connecting TIO to the GFM using 0 5 Vdc output from DB9 connector...
Страница 56: ...52 Figure 6 3 Connecting TIO to the GFM using 5 10 Vdc output from RJ11 connector...
Страница 57: ...53 Figure 6 4 Connecting TIO to the GFM using 4 20 mA output from DB9 connector...
Страница 61: ...58 Figure 6 6 Connecting TIO to the GFC Using 0 5Vdc Input Output from DB15 Connector...
Страница 62: ...59 Figure 6 7 Connecting TIO to the GFC Using 4 20mA Input Output from DB15 Connector...
Страница 68: ...65 Figure 6 9 Connecting TIO to the Generic Flow Meter...
Страница 69: ...66 Figure 6 10 Connecting TIO to the Generic Flow Controller...
Страница 95: ...92 APPENDIX D Mechanical Drawings...
Страница 96: ...93 APPENDIX E Circuit Layout Diagrams Circuit Layout Top...
Страница 97: ...94 Circuit Layout Bottom Mirror...