67
TABLE 6.5 J2 INPUT / OUTPUT JUMPER CONFIGURATION OPTIONS FOR GENERIC
FLOW METERS AND CONTROLLERS
TIO PV TYPE
J2 JUMPER CONFIGURATION
NOTE
Output
Input
J2A
J2B
J2C
J2D
J2E
J2F
0-5Vdc 0-5Vdc
2 - 3
5 - 6
8 - 9
10-11 14-15
17-18
0-5Vdc
4-20
mA
2 - 3
5 - 6
8 - 9
10-11 13-14
16-17
4 – 20
mA
0-5Vdc
1 - 2
4 - 5
7 - 8
10-11 14-15
17-18
4 – 20
mA
4 – 20
mA
1 - 2
4 - 5
7 - 8
10-11 13-14
16-17
N/A
5-10
Vdc
2 - 3
5 - 6
8 - 9
11-12 14-15
17-18
Ex5Vdc
reference signal must
be connected to pin 9
0 - 10
Vdc
0 - 10
Vdc
2 - 3
5 - 6
8 - 9
11-12 14-15
17-18
Special Order option!
(PCB hardware must be
changed)
0 - 10
Vdc
4 – 20
mA
2 - 3
5 - 6
8 - 9
10-11 13-14
16-17
Special Order option!
(PCB hardware must be
changed)
4 – 20
mA
0 - 10
Vdc
1 - 2
4 - 5
7 - 8
11-12 14-15
17-18
Special Order option!
(PCB hardware must be
changed)
0-5Vdc
0 - 10
Vdc
2 - 3
5 - 6
8 - 9
11-12 14-15
17-18
Special Order option!
(PCB hardware must be
changed)
0 - 10
Vd
0-5Vdc
2 - 3
5 - 6
8 - 9
10-11 14-15
17-18
Special Order option!
(PCB hardware must be
changed)
NOTE: Your TIO device input / output jumpers were configured at the
factory according to your order. There is no need to change input /
output jumper’s configuration unless different input is being used.
Before applying power and process signals, make sure the input /out
put jumpers are installed in the correct position (See Table 6.5).
,
c) Input/Output Jumper Configuration
Содержание TIO
Страница 14: ...10 Figure 4 3 RS 485 Multidrop Half Duplex Two Wire System...
Страница 55: ...51 Figure 6 2 Connecting TIO to the GFM using 0 5 Vdc output from DB9 connector...
Страница 56: ...52 Figure 6 3 Connecting TIO to the GFM using 5 10 Vdc output from RJ11 connector...
Страница 57: ...53 Figure 6 4 Connecting TIO to the GFM using 4 20 mA output from DB9 connector...
Страница 61: ...58 Figure 6 6 Connecting TIO to the GFC Using 0 5Vdc Input Output from DB15 Connector...
Страница 62: ...59 Figure 6 7 Connecting TIO to the GFC Using 4 20mA Input Output from DB15 Connector...
Страница 68: ...65 Figure 6 9 Connecting TIO to the Generic Flow Meter...
Страница 69: ...66 Figure 6 10 Connecting TIO to the Generic Flow Controller...
Страница 95: ...92 APPENDIX D Mechanical Drawings...
Страница 96: ...93 APPENDIX E Circuit Layout Diagrams Circuit Layout Top...
Страница 97: ...94 Circuit Layout Bottom Mirror...