71
INDEX
NAME
DATA TYPE
NOTES
0
BlankEEPROM[10]
char[10]
Do not modify. Table Revision [PROTECTED]
1
SerialNumber[20]
char[20]
Serial Number [PROTECTED]
2
ModelNumber[20]
char[20]
Model Number [PROTECTED]
3
SoftwareVer[10]
char[10]
Firmware Version [PROTECTED]
4
ManufReservedF1
float
Manufacture Specific float data [PROTECTED]
5
ManufReservedF2
float
Manufacture Specific float data [PROTECTED]
6
ManufReservedF7
float
Manufacture Specific float data [PROTECTED]
7
ManufReservedF8
float
Manufacture Specific float data [PROTECTED]
8
ReservedText[12]
char[12]
Reserved for Manufacture Specific Text Info [PROTECTED]
9
ManufReservedF3
float
Manufacture Specific float data [PROTECTED]
10
ManufReservedF4
float
Manufacture Specific float data [PROTECTED]
11
ManufReservedF5
float
Manufacture Specific float data [PROTECTED]
12
ManufReservedF6
float
Manufacture Specific float data [PROTECTED]
13
ManufReservedUI1
uint
Manufacture Specific uint data [PROTECTED]
14
ManufReservedUI2
uint
Manufacture Specific uint data [PROTECTED]
15
ManufReservedUI3
uint
Manufacture Specific uint data [PROTECTED]
16
ManufReservedUI4
uint
Manufacture Specific uint data [PROTECTED]
17
ManufReservedSI1
int
Manufacture Specific int data [PROTECTED]
18
ManufReservedSI2
int
Manufacture Specific int data [PROTECTED]
19
ManufReservedSI3
int
Manufacture Specific int data [PROTECTED]
20
TimeSinceCalHr
float
Time elapsed since last calibration in hours
21
ProtectionCode
uint
Program Parameters Protection Code [0-255]
22
DeviceFunction
uint
Device Function:0-FlowMeter,1-FlowController
23
BaudRate
uint
Comm. Interface Baude Rate Index [0-7]
24
Address485
char[4]
Two hexadecimal characters address for RS485 only [01-FF]
25
FlowUnits
int
Current Units of Measure [0-46]
26
UDUnitKfactor
float
Current Units of Measure [0-46]
27
UDUnitTimeBase
int
User-Defined Unit Time base index:[0-3]
28
UDUnitDensity
uint
User-Defined Unit use density flag 1-'Y', 0-'N'
29
KfactorMode
uint
0-Disabled, 1-Internal, 2-User-Defined
30
KfactorIndex
uint
Internal K-Factor Index [0-21]
31
UserDefKfactor
float
User-defined K-Factor
32
DiagEventMask
uint
Mask for Diagnostic Events: Clear bit-> mask
33
PSP_Mode
uint
Mode for Program SP: 0-disabled, 1-enabled
APPENDIX A
TIO Totalizer Input/Output Flow Monitor/Controller EEPROM Variables
Rev.A001 [08/10/2011]
Содержание TIO
Страница 14: ...10 Figure 4 3 RS 485 Multidrop Half Duplex Two Wire System...
Страница 55: ...51 Figure 6 2 Connecting TIO to the GFM using 0 5 Vdc output from DB9 connector...
Страница 56: ...52 Figure 6 3 Connecting TIO to the GFM using 5 10 Vdc output from RJ11 connector...
Страница 57: ...53 Figure 6 4 Connecting TIO to the GFM using 4 20 mA output from DB9 connector...
Страница 61: ...58 Figure 6 6 Connecting TIO to the GFC Using 0 5Vdc Input Output from DB15 Connector...
Страница 62: ...59 Figure 6 7 Connecting TIO to the GFC Using 4 20mA Input Output from DB15 Connector...
Страница 68: ...65 Figure 6 9 Connecting TIO to the Generic Flow Meter...
Страница 69: ...66 Figure 6 10 Connecting TIO to the Generic Flow Controller...
Страница 95: ...92 APPENDIX D Mechanical Drawings...
Страница 96: ...93 APPENDIX E Circuit Layout Diagrams Circuit Layout Top...
Страница 97: ...94 Circuit Layout Bottom Mirror...