Command Set
Switch to Command Mode
The
switch to command mode
command instructs the EmbeddedBlue module to
enter Command Mode.
Syntax
<2 second pause>
esc sequence
<2 second pause>
Parameters
esc sequence
Three consecutive instances of the escape character. The
factory default escape character is the plus sign (+). A
different escape character can be set by using the Set
Escape Character command.
Example
>con 00:0C:84:00:07:D7<CR>
Command
Mode
ACK<CR>
>This text is sent in data mode<CR>
Data Mode
<2 second pause>+++<2 second pause><CR>
>get addr<CR>
ACK<CR>
Command
Mode
00:0C:84:00:05:29<CR>
>ret<CR>
ACK<CR>
>This text is sent in data mode<CR>
Data Mode
<2 second pause>+++<2 second pause><CR>
>dis<CR>
Command
Mode
ACK<CR>
>