Low Battery Hold cycles can be set between 1 and 10 cycles. Increments of one
cycle.
• Press and release the centre button to increase cycles.
• Press and release the left-hand button to decrease the cycles.
• Press and release the right-hand button to move onto the next option.
This must be set 10 seconds greater than the curtain with the longest run time
for the bottom bar to fully retract and hit the head box.
Once the timer has counted down the power to the motor is transferred to the
brake and the motor stall power is switched off.
If set to disabled the motor will remain in stall and the power will not transfer
to the brake unit. This feature is programmed to enable the use of non braked
motors.
• This can be set between Disabled 0 and 600 seconds
• Press and release the centre button to increase the seconds.
• Press and hold the centre button to increase the seconds by 10.
• Press and release the left-hand button to decrease the seconds.
• Press and hold the left-hand button to decrease the seconds by 10.
• Press and release the right-hand button to move onto the next option.
Low battery hold/drop cycles
Curtain open
49
Содержание Evo1-MCP 1
Страница 4: ...Back to contents Mechanical Installation Instructions 4...
Страница 17: ...Back to contents Control Panel Lighting 17...
Страница 20: ...Back to contents Motor Control Board Lighting 20...
Страница 22: ...Back to contents General Overview Instructions 22...
Страница 25: ...Back to contents Control Panel Wiring 25...
Страница 30: ...Back to contents Motor Control Board Wiring 30...
Страница 36: ...Back to contents Dip Switch Settings 36...
Страница 39: ...Back to contents Override Switch Wiring to Control Panel 39...
Страница 41: ...Back to contents Override Switch Wiring to Motor Control Board 41...
Страница 44: ...Back to contents Control Panel Function Programming 44...
Страница 54: ...Back to contents Optional Extras 54...
Страница 58: ...Wiring of Optional Extras 58...
Страница 64: ...Back to contents Fault Finding 64...
Страница 67: ...Back to contents Maintenance Service 67...
Страница 71: ...EVO System Maintenance Record Date Date Date Action Taken Action Taken Action Taken Engineer Engineer Engineer...
Страница 72: ...EVO System Maintenance Record Date Date Date Action Taken Action Taken Action Taken Engineer Engineer Engineer...
Страница 73: ...EVO System Maintenance Record Date Date Date Action Taken Action Taken Action Taken Engineer Engineer Engineer...
Страница 74: ...Back to contents Standard Drawings Headbox and Guides 74...
Страница 84: ...Back to contents 44 0 1204 383839 info a1shutters co uk www a1sgroup com...