background image

1.  Symbols  and  abbreviations  used

operation  manual

ENVIRONMENT:

Danger  high  voltage.

Make  use  of  the  certified  and  professional  recycling  service  of  
our  AKKU  SYS  team.

WARNING!

Warning  when  handling  accumulators.

Identifies  assemblies  or  parts  that  must  be  disposed  of  properly.  Do  not  throw  them  
in  the  household  waste.

on  the  hotline  +49  4101/3  76  76-0,  

[email protected]  

or  use  the  

QR  code:

General  warning  of  danger  spots.

This  symbol  indicates  text,  hints  or  tips.

These  are  also  referred  to  as  PV  systems .

In  this  manual,  the  abbreviation  MPPT  stands  for:  Maximum  Power  
Point  Tracking.

A  NOTICE:

Indicates  information  about  recycling.

Warnings  and  notes  are  identified  by  the  appropriate  symbols  (pictograms)  and  must  be  
observed:

Failure  to  take  preventive  protective  measures  may  result  in  damage  to  the  product  

and/or  its  functions  or  something  in  its  vicinity.

Accumulators  are  usually  used  as  energy  stores  in  a  PV  system .  These  are  colloquially  
referred  to  as  rechargeable  batteries  or  batteries.

Solar  charge  controllers  are  used  in  connection  with  a  photovoltaic  system.

For  more  information  contact  us  by  phone

MPPT  Solar  Charge  Controllers  A100/20,  A100/40,  A150/60

page  

6

02/2022  

Machine Translated by Google

Содержание A100/20

Страница 1: ...rge controller 9887580 9887584 a TroniX MPPT Solar Charge Controller A100 20 a TroniX MPPT Solar Charge Controller A100 40 a TroniX MPPT Solar Charge Controller A150 60 item number 9887582 Model A100...

Страница 2: ...weg 23 25469 Halstenbek Hamburg GERMANY Telephone 49 4101 3 76 76 0 Fax 49 4101 3 76 76 66 info akkusys de www akkusys de 02 2022 page 2 MPPT Solar Charge Controllers A100 20 A100 40 A150 60 The publi...

Страница 3: ...ropriate information in these operating instructions Read carefully before use The solar charge controller is based on advanced MPPT technology specially developed for solar systems We assume no liabi...

Страница 4: ...s A100 40 4 4 Installation positions A100 40 4 5 Dimensions A150 60 4 6 Installation positions A150 60 19 20 5 4 Connecting accessories 17 6 13 18 21 20 15 4 10 Bluetooth communication 16 Page 8 5 8 F...

Страница 5: ...Solar Charge Controllers A100 20 A100 40 A150 60 27 32 25 6 11 Charging modes 23 26 6 3 LCD display 6 4 Error display 6 5 Parameter setting 6 6 Undervoltage protection 6 7 Reconnection voltage 6 8 Blu...

Страница 6: ...this manual the abbreviation MPPT stands for Maximum Power Point Tracking A NOTICE Indicates information about recycling Warnings and notes are identified by the appropriate symbols pictograms and mu...

Страница 7: ...safety instructions Only use the solar charge controller in connection with the intended photovoltaic systems Be sure to follow all warnings and instructions in this manual Only transport the solar c...

Страница 8: ...fe is extended by a precise temperature sensor Batteries can produce flammable and possibly toxic gases oxyhydrogen Avoid creating any sparks near the battery The device has a double automatic protect...

Страница 9: ...rent must be proportionately greater than the solar input current to balance the input and output power Monthly load data can be displayed as a summary in the form of graphics Always on dusk evening a...

Страница 10: ...d the solar system The greater the difference between the battery voltage and the Vmp of the module the more energy is wasted In contrast to conventional PWM solar charge controllers pulse width modul...

Страница 11: ...ed the PV charge current the solar charge controller will no longer be able to keep the battery at the float charge setpoint If the battery voltage remains below the quick recharge voltage the charge...

Страница 12: ...ach full charge to avoid over voltage and or overheating of the battery Certain battery types benefit from periodic equalization charging WARNING By balancing the charge the battery voltage increases...

Страница 13: ...ce description 4 1 Dimensions A100 20 operation manual Dimensions mm 02 2022 page 13 4 2 The installation position A100 20 MPPT Solar Charge Controllers A100 20 A100 40 A150 60 Machine Translated by G...

Страница 14: ...4 3 Dimensions A100 40 4 4 Installation positions A100 40 operation manual 02 2022 page 14 Dimensions mm MPPT Solar Charge Controllers A100 20 A100 40 A150 60 Machine Translated by Google...

Страница 15: ...4 5 Dimensions A150 60 4 6 Installation positions A150 60 operation manual page 15 02 2022 Dimensions mm MPPT Solar Charge Controllers A100 20 A100 40 A150 60 Machine Translated by Google...

Страница 16: ...ble lengths must be ordered separately 6 RJ11 interface The sensor is connected via interface 5 2 plastic housings to protect internal components 3 LED LCD display to show settings and working status...

Страница 17: ...LE technology A NOTICE 2 Realizes the solar charge controller wireless monitoring function There are two options For operation details refer to the Bluetooth app instructions The solar charge controll...

Страница 18: ...around the device should be kept free for unhindered air circulation Attach it so that the cable holes are facing down Fix it upright on the wall Make sure that this is a non combustible wall material...

Страница 19: ...h out for this hazard First drill the 4 mounting holes according to the installation positions in 5 Device description on the wall The inside temperature is automatically displayed if no solar charge...

Страница 20: ...nominal voltage of 24 V DC the battery voltage should be in the range of 20 0 to 31 0 V DC To avoid tension in the cables wires first connect them to the load before connecting them to the solar charg...

Страница 21: ...are in the immediate vicinity of the ATTENTION For systems with common negative poles such as mobile homes the use of a common negative pole solar charge controller is recommended device Keep a dista...

Страница 22: ...V Module off undervoltage protection off overheat protection Flashing slowly 0 5 2 s Green on Short circuit or over current protection No communication Blink 0 5 0 5 s Flashing slowly 0 5 2 s The PV m...

Страница 23: ...matically after 30 seconds PV Strom Simultaneously press the MENU and OK buttons for one second The LCD display stops scrolling Position pause display OK Set parameters Status Advertisement MENU Press...

Страница 24: ...arge amp hours Status Temperature A NOTICE PV Module Symbol Battery type adjustable Load mode adjustable Total PV amp hours reconnection voltage LVR adjustable Last The PV ampere hours PV panel kit an...

Страница 25: ...h the interface Battery status shows full error icon display battery frame flashes LCD display shows E4 order as follows Load off battery status shows empty error icon display battery frame flashes LC...

Страница 26: ...LVD you must first increase the LVR value set the voltage protection of the solar charge controller The turn on voltage LVR should be at least 0 6 1 2 2 4V higher than the under voltage lockout LVD P...

Страница 27: ...nfirm with OK to reset the set password via the mobile app When choosing a liquid gel or AGM battery the charging parameters boost equalize and float voltage can be set via mobile phone app RS485 or W...

Страница 28: ...age Dusk to Sunrise The load output stays on from sunset to sunrise 12 24 V 10 32 V Standard 14 4 V The solar charge controllers of the a TroniX series are suitable for all types of lithium batteries...

Страница 29: ...ht delay time 0 30 minutes default 0 30 minutes Dusk to Sunrise When the load is set to Dusk to Sunrise the day night threshold voltages and day night delay time can be set via RS485 or Bluetooth App...

Страница 30: ...is switched on again Full protection against battery polarity reversal no damage to the solar charge controller Correct the connection to resume normal operation Battery low voltage Mistake Caused Ca...

Страница 31: ...hort circuit occurs the load will short circuit while charging Description Damaged remote temperature sensor damaged the solar charge controller automatically adopts the internal temperature This prev...

Страница 32: ...corrective action as soon as possible Make use of the certified and professional recycling service of our AKKU SYS team If necessary take corrective action Electric shock hazard Make sure all power i...

Страница 33: ...n Twilight Night Manual before the boost or equalizer charging stage 14 14 8 28 29 6 25 C default 14 5 29 14 15 0 28 30 25 C default 14 8 29 6 Designation 4 17 per cell boost balance 3 33 per cell mai...

Страница 34: ...uid AGM battery 13 14 5 26 29 39 43 5 52 58 25 C 0 83 99 9 Power connections mm Optional Own consumption mA 16 6AWG Standard 14 5 29 43 5 58 14 15 28 30 42 45 56 60 25 C Float Voltage V Maximum effici...

Страница 35: ...0 64 0 Lithium Standard 29 4 Standard 8 16 24 32 loT 99 9 16 6AWG Lithium Standard 28 7 Permanent On Twilight Night Manual Ambient temperature C Bluetooth RS485 RJ25 6P2C interface IP32 low voltage P...

Страница 36: ...talog Other manufacturers and product areas can be found in ours 02 2022 AKKU SYS Accumulator and Battery Technology North GmbH Verbindungsweg 23 25469 Halstenbek Hamburg GERMANY Telephone 49 4101 3 7...

Отзывы: