13. If applicable, set the temperature value back to the original value (parameter
002
).
14. Set parameter
201
to
dIS
15. Press [RESET]. The water heater goes into OFF mode.
16. Set the control switch on the side of the water heater to 0 to turn off the water
heater.
17. Remove the measurement probe of the CO
2
meter from the test nipple and place the
cap (1) back on the nipple (2).
18. Shut off the gas supply.
Fig. CO
2
value
1
2
1. Cap
2. Test nipple
8.9.5
Turn on the water heater
Refer to the procedure in the user part to Turn on the water heater (see 4.2).
8.10
Decommisioning
To decommission the water heater:
1.
Turn off the water heater (see 8.10.1)
2.
Drain the water heater (see 8.10.2)
8.10.1
Turn off the water heater
Refer to the procedure in the user part to Turn off the water heater (see 4.3) and isolate
the water heater from the mains power supply.
8.10.2
Draining
Refer to the installation diagram (see 8.3) when you drain the water heater:
1.
Close the manual gas valve (10).
2.
If applicable, close the service stop valve (11) in the hot water pipe.
3.
Close the stop valve (10).
4.
Open the drain valve (9).
5.
Aerate the entire installation of air until the water heater is completely drained.
0312266_INNOVO_UKUK_
V5.1, 2022-07-12
55
Содержание Innovo IR 12-160
Страница 6: ...6 ...
Страница 13: ...User part 0312266_INNOVO_UKUK_V5 1 2022 07 12 13 ...
Страница 14: ...14 ...
Страница 16: ...16 User part ...
Страница 18: ...18 User part ...
Страница 24: ...24 User part ...
Страница 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V5 1 2022 07 12 27 ...
Страница 28: ...28 User part ...
Страница 36: ...36 Installation Maintenance and Service part ...
Страница 56: ...56 Installation Maintenance and Service part ...
Страница 58: ...58 Installation Maintenance and Service part ...
Страница 70: ...70 Installation Maintenance and Service part ...
Страница 83: ...0312266_INNOVO_UKUK_V5 1 2022 07 12 83 ...
Страница 87: ...13 4 Electrical wiring diagram 0312266_INNOVO_UKUK_V5 1 2022 07 12 87 ...
Страница 89: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V5 1 2022 07 12 89 ...
Страница 90: ......
Страница 91: ......
Страница 94: ...92 Installation Maintenance and Service part ...