110 Indoor / 110 Outdoor Service Manual
Ver. 1.01
24
CONFIDENTIAL
10-8. Flow adjustment valve
Unit Part #
#402
AOS Part #
319143-167
Checkpoint
J
Function
Controls water flow to properly control the output hot water temperature.
Failure events
1. Water leakage from valve.
2. The valve cannot modulate or make open/close positions.
Effects on the water
heater if flow adjustment
valve fails
1. Water leakage from failed valve can damage other water heater
components.
2. Temperature fluctuations in the hot water output.
Error codes when flow
adjustment valve fails
N/A
Diagnostic
1. Visual inspection: connection/breakage of wires, motor drive locked due
to scale buildup, and/or water leakage.
2. Check voltages and resistance; proper range of values shown below.
Color/Number of wires
Black - Red
7 to 16 VDC and 0.09 to 0.2 k
Ω
The flow adjustment valve is assembled with the flow sensor.