110 Indoor / 110 Outdoor Service Manual
Ver. 1.01
13
CONFIDENTIAL
Check-
point
Part and Description
Color of wires
Normal range
H1
Gas proportional valve
White - red
1 to 15 VDC (during operation)
and
20 to 40
Ω
H2
Flow sensor
Red - Black
4 to 5.5 VDC
White - Black
1 to 4 VDC (pulse)
1,080 pulse / min
(more than 18 Hz)
I
Air-fuel ratio rod
Yellow - AFR rod
(Between AFR rod and
the computer board)
More than 0.5
μ
A
(during operation)
Flame rod
Orange - Flame rod
(Between flame rod and
the computer board)
More than 1
μ
A
(during operation)
J
Flow adjustment valve
Red - Black
7 to 16 VDC and 0.09 to 0.2 k
Ω