110 Indoor / 110 Outdoor Service Manual
Ver. 1.01
15
CONFIDENTIAL
9. Operational flow chart
The diagram below refers to both 110 Indoor and 110 Outdoor.
Power supply ON
Operation SW ON
FAV open
Pre-check
NORMAL?
Faucet opens
Water Flow
Above 0.75GPM?
FM speed
(Below
1,000rpm?)
Fan moter start
operation
False flame
Below
DC0.15 A?
Igniter ON
Hi-limit
Normal?
OHCF
Normal?
MV ON
SV2 ON
GPV ON
Flame rod
detects Above
DC1.0 A?
Burning lamp ON
Igniter OFF
Proportional control
BTU
change over
point?
SV1 SV3 ON
Below water
heat capability?
FAV OPEN
Safety devices
sensed
abnormal condition
FAV close
SV1 SV3 OFF
False Dipswitch
settings
InTH failure
SV circuit failure
MV circuit failure
03 blink
32 blink
51 blink
55 blink
61 blink
Fan motor stop
operation
72 blink
False flame
Igniter OFF
Reignition
Success?
OuTH OPEN
or SHORT
Fan motor
fault
MV OFF
SV2 OFF
GPV OFF
SV1 SV3 OFF
Fan motor stop operation
Faucet closes
Flow sensor OFF
Remove cause
Opeartion lamp OFF
Operation stop
YES
NO
YES
NO
NO
YES
YES
NO
(20sec later)
YES
NO
NO
YES
YES
NO
YES
NO
(5sec later)
YES
YES
NO
YES
NO
(20sec later)
YES
NO
NO
NO
YES
FM speed
(Above
1,000rpm?)
Below
Max flow rate
restriction?
11 blink
12 blink
31 blink
OuTH failure
31 blink
PCB failure
70 blink
Flame
blows out
OHCF melted
(above 430 F)
AFR rod failure
Abnormal
burning
12 blink
12 blink
99 blink
39 blink
32 blink
InTH OPEN
or SHORT
61 blink
FAV ; Flow Adjustment Valve
F M ; Fan Motor
OHCF; Over Heat Cut-off Fuse
M V ; Main gas Valve
SV1 ; Solenoid Valve 1
(See the section 6)
SV2 ; Solenoid Valve 2
(See the section 6)
SV3 ; Solenoid Valve 3
(See the section 6)
GPV ; Gas Proportional Valve
InTH; Inlet thermistor
OuTH; Outlet thermistor
PCB ; Print Circuit board
(Computer board)
AFR ; Air Fuel Ratio rod