110 Indoor / 110 Outdoor Service Manual
Ver. 1.01
3
CONFIDENTIAL
1. Specifications of the 110 Direct Vent Indoor* and 110 Outdoor
Model
110 Indoor
110 Outdoor
Dimensions
H20.5"×W13.8"×D6.7"
Weight
33 lbs.
Co
m
bu
st
io
n
INPUT
BTU/h
Max
140,000
Min
19,500
Combustion System
Power vent
Installation
Indoor & Direct-vent
Outdoor
Fan motor
PWM Multi blade fan
Manifold
Pressure**
Max
LP 2.6” WC
Natural 2.2” WC
LP 3.0” WC
Natural 2.7” WC
Min
LP 0.7” WC
Natural 0.6” WC
LP 0.8” WC
Natural 0.7” WC
W
at
er
c
on
tr
ol
Flow rate
0.75 to 6.6 GPM
Available set
temperatures
99°F to 167°F
Default: 122°F
Temperature
dipswitch settings
113°F, 122°F, 131°F, 140°F
Bypass valve
N/A
Thermistors
2 thermistors (In, Out)
O
pe
ra
tio
n
Remote controller
model
9007666005
PCB model
110
Indicators
Red LED on PCB during operation
Power supply
control
Surge absorber and Power ON-OFF switch
Fe
at
ur
es
Freeze protection
Ceramic heaters
Self-combustion
improvement
Air-Fuel Ratio Detection System
Easy-Link system
N/A
Multiple-system
N/A
* The 310 Direct Vent Indoor means the 110 Indoor in the text.