8. Resistance values of the temperature thermistors
The 110 Indoor and 110 Outdoor use the same thermistors.
ºF
32
41
50
59
68
77
86
95
104
113
ºC
0
5
10
15
20
25
30
35
40
45
Resistance
k
Ω
23.76
19.08
15.43
12.56
10.28
8.47
7.02
5.85
4.90
4.12
Tem perature
ºF
122
131
140
149
158
167
176
185
194
203
212
ºC
50
55
60
65
70
75
80
85
90
95
100
Resistance
k
Ω
3.49
2.96
2.53
2.16
1.86
1.60
1.39
1.21
1.05
0.92
0.81
T e mperature(ºF) vs. Re sistance (k
Ω
)
T e mperature(
℃
) v s. Resistance(k
Ω
)
Tem perature
0.00
5.00
1 0.00
1 5.00
2 0.00
2 5.00
2 0
40
6 0
80
10 0
12 0
140
16 0
180
2 00
22 0
Tem p erature (ºF)
R
e
s
is
it
a
n
c
e
(
k
Ω
)
0.0 0
5.0 0
10.0 0
15.0 0
20.0 0
25.0 0
0
1 0
20
3 0
40
50
60
7 0
80
9 0
10 0
Tem pe ra tu re (ºC)
R
e
s
is
it
a
n
c
e
(
k
Ω
)
Resistance values at different temperatures