UF-216 WATER FILTRATION SYSTEM

2

P/N 1010885 07/04

UF-216 WATER FILTRATION SYSTEM

3

P/N 1010885 07/04

Purchased From:

Date of Purchase:

Model No.:

Serial No.:

Mfg. No.:

Throughout this manual, you will find the following 

safety words and symbols that signify important safety 

issues with regards to operating or maintaining the unit.

WARNING

GENERAL WARNING.  Indicates informa-

tion important to the proper operation of 

the equipment.  Failure to observe may 

result in damage to the equipment and/or 

severe bodily injury or death.

WARNING

ELECTRICAL WARNING.  Indicates infor-

mation relating to possible shock hazard.  

Failure to observe may result in damage 

to the equipment and/or severe bodily 

injury or death.

CAUTION

GENERAL CAUTION.  Indicates informa-

tion important to the proper operation of 

the equipment.  Failure to observe may 

result in damage to the equipment.

IMPORTANT SAFETY INFORMATION

In addition to the warnings and cautions in this manual, 

use the following guidelines for safe operation of the 

unit.

     •  Read all instructions before using equipment.

     •  For your safety, the equipment is furnished with 

a properly grounded cord connector.  Do not 

attempt to defeat the grounded connector.

     •  Install or locate the equipment only for its intend-

ed use as described in this manual.  Do not use 

corrosive chemicals in this equipment.

     •  Do not operate this equipment if it has a dam-

aged cord or plug; if it is not working properly, or 

if it has been damaged or dropped.

     •  This equipment should be serviced by qualified 

personnel only.  Contact Antunes Equipment 

Manufacturing (Suzhou) Co., Ltd. at 

86-512-684-

3637

 for repair

     •  Do not immerse cord or plug in water.

Service/Technical Assistance

If you experience any problems with the installation 

or operation of your unit, contact Antunes Equipment 

Manufacturing (Suzhou) Co., Ltd. at 

86-512-684-3637

.

Fill in the information in the next column and have it 

handy when calling for assistance.  The serial number 

is on the specification plate located on the unit.

OWNER INFORMATION (continued)

IMPORTANT

Antunes Filtration Technologies reserves the right to change specifications and product 

design without notice.  Such revisions do not entitle the buyer to corresponding chang-

es, improvements, additions or replacements for previously purchased equipment.

Содержание UF-216C Series

Страница 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...

Страница 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and ar...

Страница 3: ...afety the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this...

Страница 4: ...TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a prope...

Страница 5: ...ualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cart...

Страница 6: ...UF 216 WATER FILTRATION SYSTEM 6 P N 1010885 07 04 SPECIFICATIONS continued Figure 2a Components Components Inlet Nipple Permeate Nipple Drain Nipple Power Cord Shroud...

Страница 7: ...UF 216 WATER FILTRATION SYSTEM 7 P N 1010885 07 04 LED Display Program Button Power Cord Filter Cartridge Strainer Permeate Drain Inlet Figure 2b Components SPECIFICATIONS continued Components...

Страница 8: ...r to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or Teflon tape on pipe threads Be careful not to get the pipe sealant inside the pipe when making t...

Страница 9: ...line Check with local codes for the proper specification DRAIN LINE PLUMBING The drain line is used to flush away the particle buildup when cleaning the filter The drain line must be able to support...

Страница 10: ...nd FL will appear on the display 5 Continue holding the Start button down for at least CAUTION Ingesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or o...

Страница 11: ...ends of the Carbon Cartridge before inserting into the Carbon Filter Housing Place the Carbon Cartridge into the Housing and screw the Housing up into the Filter Housing Cap 5 Slowly open the inlet w...

Страница 12: ...drains 5 When the water flow out of the strainer stops pour the liquid bleach into the strainer Be care ful not to spill bleach onto clothing or skin You may want to add the bleach using a cup or fun...

Страница 13: ...ater After a certain period of time depending upon water quality the filter has to be cleaned This is accom plished through the Flush Duration Mode During this mode the drain valve opens and flushes t...

Страница 14: ...and release start but ton to view current setting Figure 7 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 8 4 After ten seconds...

Страница 15: ...ter fifty minutes they are displayed in hours Table B TO SET Fd FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure...

Страница 16: ...for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasi...

Страница 17: ...hange the Carbon Filter Cartridge follow the steps under Install and Flush the Carbon Filter Cartridge in the Installation section of this manual CHANGING THE CAPILLARY MEMBRANE FILTER CARTRIDGE 1 Ope...

Страница 18: ...exceeded it s filtration capacity Replace the Carbon Cartridge Filter Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken capillary i...

Страница 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...

Страница 20: ...ousing 10 1 7 1001149 Label Shroud 1 8 2090139 Cartridge Carbon Block 1 9 3080103 Screw MACH 8 32 x 1 4 1 Item Part Description Qty No Item Part Description Qty No SLTRSHD 10 1001083 Label Drain 1 11...

Страница 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...

Страница 22: ...984 Mounting Bracket 2 1 15 2090120 Cartridge Filter 2 x 16 1 16 2180173 Connector Slide 2 2 17 2180177 Cap End 2 2 18 0200219 O Ring 2 4 19 2190133 Tee Strainer 1 2 NPT 1 20 2090129 Screen Tee Strain...

Страница 23: ...P N 1010885 07 04 WIRING DIAGRAM TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFI...

Страница 24: ...zed service agency to reach the equipment location 2 Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to...