Unpacking

   1.  Remove the system and all packing materials 

from the chipping carton.

   2.  Remove all packing materials and protective cov-

erings from the system

   3.  Remove the information packet.  To prevent any 

delay in obtaining warranty coverage, fill out and 

mail the warranty card.

NOTE:  If any parts are damaged, contact Antunes 

Equipment Manufacturing (Suzhou) Co. Ltd. 

IMMEDIATELY at 88-512-684-3637.

Equipment Setup

GENERAL

When placing the unit into service, pay attention to the 

following guidelines:

     •  Make sure power to the unit is off.

     •  Do not immerse cord or plug in water.

     •  Keep cord away from heated surfaces.

ELECTRICAL

Ensure that the line voltage corresponds to the stated 

voltage on the units specification label.  Make sure that 

the plug on the power cord from the system and the 

outlet match.  For proper operation, and to ensure the 

highest quality water from the system, make sure that 

the system is not connected to a switched electrical 

outlet.

PLUMBING

NOTE:  This unit is designed to use tap water not 

to exceed 104°F (40°C).

The UF-216 uses the following connections (Figure 1):

 

•  Water Inlet  

 

 

1/2” NPT

•  Permeate (Product Water) 

1/2” NPT

•  Drain   

 

 

1/2” NPT

When making a plumbing connection to the system, 

remember to use a back-up wrench on the supporting 

plumbing.  Always use a good quality, approved, pipe 

sealant or Teflon tape on pipe threads.  Be careful not 

to get the pipe sealant inside the pipe when making the 

connections.  

INSTALLATION

Do not

 over tighten the connections.  It is recommend-

ed that plastic fittings be used when connecting to the 

plastic connections of the system.  This will reduce the 

possibility of  cracking the connections due to overtight-

ening.  

If soldered plumbing is used, do not apply heat to, or 

near, the filtration system.  The use of union (O-ring 

seal) connections is highly recommended for ease of 

installation and future servicing.

SUGGESTED TOOLS AND SUPPLIES FOR INSTALLATION

The following tools and supplies are suggested to make 

the installation easier:

•  Screwdriver

•  Drill with bits

•  Strap wrench 

  (up to 6” diameter)

•  Tape measure

•  Two gallon bucket

•  Fresh 5 1/4% liquid 

  chlorine bleach

  (such as Clorox®) 

•  Adjustable wrenches

•  Pipe wrenches

•  Level

•  Pipe dope or Teflon  

  tape

CAUTION

This equipment is to be installed to comply with 

the basic plumbing code of the Building Officials 

and Code Administrators, Inc. (BOCA) and the 

Food Service Sanitation Manual of the Food and 

Drug Administration (FDA).

CAUTION

Water pressure must not exceed a membrane 

burst pressure of 7 bar (100 psi).  To reduce water 

pressure, install a water pressure regulator and 

set water pressure to suit application.  Note that 

trans membrane pressure must be .5 - 2.5 bar (7 

- 36 psi).

Содержание UF-216C Series

Страница 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...

Страница 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and ar...

Страница 3: ...afety the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this...

Страница 4: ...TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a prope...

Страница 5: ...ualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cart...

Страница 6: ...UF 216 WATER FILTRATION SYSTEM 6 P N 1010885 07 04 SPECIFICATIONS continued Figure 2a Components Components Inlet Nipple Permeate Nipple Drain Nipple Power Cord Shroud...

Страница 7: ...UF 216 WATER FILTRATION SYSTEM 7 P N 1010885 07 04 LED Display Program Button Power Cord Filter Cartridge Strainer Permeate Drain Inlet Figure 2b Components SPECIFICATIONS continued Components...

Страница 8: ...r to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or Teflon tape on pipe threads Be careful not to get the pipe sealant inside the pipe when making t...

Страница 9: ...line Check with local codes for the proper specification DRAIN LINE PLUMBING The drain line is used to flush away the particle buildup when cleaning the filter The drain line must be able to support...

Страница 10: ...nd FL will appear on the display 5 Continue holding the Start button down for at least CAUTION Ingesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or o...

Страница 11: ...ends of the Carbon Cartridge before inserting into the Carbon Filter Housing Place the Carbon Cartridge into the Housing and screw the Housing up into the Filter Housing Cap 5 Slowly open the inlet w...

Страница 12: ...drains 5 When the water flow out of the strainer stops pour the liquid bleach into the strainer Be care ful not to spill bleach onto clothing or skin You may want to add the bleach using a cup or fun...

Страница 13: ...ater After a certain period of time depending upon water quality the filter has to be cleaned This is accom plished through the Flush Duration Mode During this mode the drain valve opens and flushes t...

Страница 14: ...and release start but ton to view current setting Figure 7 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 8 4 After ten seconds...

Страница 15: ...ter fifty minutes they are displayed in hours Table B TO SET Fd FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure...

Страница 16: ...for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasi...

Страница 17: ...hange the Carbon Filter Cartridge follow the steps under Install and Flush the Carbon Filter Cartridge in the Installation section of this manual CHANGING THE CAPILLARY MEMBRANE FILTER CARTRIDGE 1 Ope...

Страница 18: ...exceeded it s filtration capacity Replace the Carbon Cartridge Filter Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken capillary i...

Страница 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...

Страница 20: ...ousing 10 1 7 1001149 Label Shroud 1 8 2090139 Cartridge Carbon Block 1 9 3080103 Screw MACH 8 32 x 1 4 1 Item Part Description Qty No Item Part Description Qty No SLTRSHD 10 1001083 Label Drain 1 11...

Страница 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...

Страница 22: ...984 Mounting Bracket 2 1 15 2090120 Cartridge Filter 2 x 16 1 16 2180173 Connector Slide 2 2 17 2180177 Cap End 2 2 18 0200219 O Ring 2 4 19 2190133 Tee Strainer 1 2 NPT 1 20 2090129 Screen Tee Strain...

Страница 23: ...P N 1010885 07 04 WIRING DIAGRAM TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFI...

Страница 24: ...zed service agency to reach the equipment location 2 Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to...