![A.J.Antunes UF-216C Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/a-j-antunes/uf-216c-series/uf-216c-series_owners-manual_3123904010.webp)
UF-216 WATER FILTRATION SYSTEM
10
P/N 1010885 07/04
UF-216 WATER FILTRATION SYSTEM
11
P/N 1010885 07/04
Figure 3. Proper Draining
2”
minimum
2”
minimum
Floor
Drain
Secure
End
Drain Line
from System
Drain Line
from System
Secure
End
Drain
Standpipe
INSTALLATION (continued)
cal outlet. The display will power on and the LED
display will display the following for about two sec-
onds each:
•
8.8
•
F8
followed by its time settings in seconds
•
Fi
and its time setting in minutes or hours.
The
F8
and
Fi
sequence repeats for 30 seconds
after which the unit automatically returns to the
Flush Interval Mode (
Fi
). The time setting for
Fi
will
be displayed and the decimal point will flash in one
second intervals.
2. Open the tap or faucet closest downstream to the
filter system.
3. Slowly open the inlet water valve and allow water
to enter the system.
4. Press and hold the Start button. After 6-7 sec-
onds, the drain valve will open and
FL
will appear
on the display.
5. Continue holding the Start button down for at least
CAUTION
Ingesting the protective solution may cause irrita-
tion of the gastrointestinal tract, colic, diarrhea, or
other similar symptoms
30 seconds to keep the drain open. This flushes
air out of the center of the hollow fibers. The
drain will remain open as long as the Start button
is pressed. Check to make sure that the drain
water is directed into the drain without splashing.
6. Release the Start button. This closes the drain
valve. Water should continue to flow through the
system and out of the open tap. Allow water to
flow out of the tap for at least 15 minutes at maxi-
mum flow rate.
7. Close the tap and let the system stand with no
water flow for 15 minutes to allow any trapped air
to come out of the hollow fibers. Check for leaks
at all fittings.
8. After 15 minutes without water flow, open the
tap for 5 minutes to allow any trapped air to be
flushed out.
9. Close the tap. Flushing of the membrane car-
tridge is complete.
INSTALL AND FLUSH THE CARBON FILTER CARTRIDGE
Содержание UF-216C Series
Страница 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...
Страница 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...
Страница 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...