manualshive.com logo in svg
background image

UF-216 WATER FILTRATION SYSTEM

8

P/N 1010885 07/04

UF-216 WATER FILTRATION SYSTEM

9

P/N 1010885 07/04

INSTALLATION (continued)

Locating and Mounting the system

Consider these points before mounting the system:

•  Note the location of the water supply, drain, and 

an appropriate electrical outlet when choosing a 

mounting location.  

•  Remember to allow for access to the timer/

programmer controls.  

•  Do not mount the system above any electrical 

equipment, or items that may be damaged if they 

get wet.  

•  Install the system in a location that will allow for 

future service access.  

•  Mount the system on a wall using appropriate 

mounting hardware.  

•  Remember to consider the operating weight of 

the system when choosing mounting hardware.  

Depending on the type of wall the system is being 

mounted to, wall reinforcement may be necessary.

INLET WATER PLUMBING

It is recommended that the inlet water plumbing line 

be 1/2”” NPT or larger.  A shutoff valve (not supplied) 

should be installed in the line leading to the system.  

The valve should be mounted close to the system inlet, 

and sized properly for the inlet plumbing line.  This 

valve will allow for easier servicing and future cartridge 

change-out. 

NOTE: The system should only be connected to the 

cold water line.

To ensure that the highest quality water is produced 

from the system, the plumbing leading to the filter sys-

tem must be flushed clear of all debris before the sys-

tem is hooked up.  Before making the connection to the 

inlet of the filter system, hold a bucket or other contain-

er at the inlet water line and slowly open the inlet water 

valve.  Allow the pipe to flush until all debris is removed.

PERMEATE LINE PLUMBING

To ensure the highest quality and safest water, it is rec-

ommended that a check valve (to prevent back flow) be 

installed in the water line after the permeate connec-

tion.  This will help prevent possible contamination of 

the filter system due to other equipment downstream.  

The check valve (not supplied) should be mounted 

close to the system outlet, and sized properly for the 

plumbing line.  Check with local codes for the proper 

specification.

DRAIN LINE PLUMBING

The drain line is used to flush away the particle buildup 

when cleaning the filter.  The drain line must be able 

to support the flow rate when the system flushes.  The 

flow rate from the flush depends on the inlet water pres-

sure, inlet pipe size, and system selected.  It is recom-

mended that the drain line be as large as, or larger 

than, the inlet plumbing line.  The drain line should be 

as short as possible, sloping downward without kinks 

or loops.  Be sure that the drain used is not blocked or 

restricted.  

The filter system must be protected from possible back 

contamination by the installation of an air gap between 

the drain connection of the system and the drain 

(Figure 3).  This gap in the line, with no physical contact 

between the system and sewer, prevents contamination 

of the system in the event of a backed-up sewer.  

NOTE: Make sure that the end of the drain line is 

positioned and secured at least 2 inches above 

the drain so that the water flow is directed into the 

drain, without splashing.

Flushing and Starting the System 

FLUSH THE PIPES

To ensure that the highest quality water is produced 

from the system, the plumbing leading from the filter 

system must be flushed clear of all debris after the 

system is hooked up.  After making the connection to 

the outlet of the filter system, open a faucet or tap clos-

est to the filter system, then slowly open the inlet water 

valve.  Allow the pipe to flush until all debris is removed.

FLUSH THE MEMBRANE CARTRIDGE

The ultrafiltration membrane cartridge must be flushed 

to remove air and the shipping/storage solution.  For 

maximum quality, the permeate water produced during 

the flushing procedure must be discarded.  

Direct this 

permeate water to the drain

.  

   1.  Plug the power cord into the appropriate electri-

IMPORTANT

It is recommended that you flush the membrane 

cartridge first, 

without the carbon cartridge 

installed in the Carbon Filter Housing

, followed 

by flushing the carbon cartridge.  This prevents 

the shipping/storage solution in the membrane 

cartridge from entering the carbon cartridge and 

ensures that the system produces the highest 

quality water.

Содержание UF-216C Series

Страница 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...

Страница 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and ar...

Страница 3: ...afety the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this...

Страница 4: ...TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a prope...

Страница 5: ...ualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cart...

Страница 6: ...UF 216 WATER FILTRATION SYSTEM 6 P N 1010885 07 04 SPECIFICATIONS continued Figure 2a Components Components Inlet Nipple Permeate Nipple Drain Nipple Power Cord Shroud...

Страница 7: ...UF 216 WATER FILTRATION SYSTEM 7 P N 1010885 07 04 LED Display Program Button Power Cord Filter Cartridge Strainer Permeate Drain Inlet Figure 2b Components SPECIFICATIONS continued Components...

Страница 8: ...r to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or Teflon tape on pipe threads Be careful not to get the pipe sealant inside the pipe when making t...

Страница 9: ...line Check with local codes for the proper specification DRAIN LINE PLUMBING The drain line is used to flush away the particle buildup when cleaning the filter The drain line must be able to support...

Страница 10: ...nd FL will appear on the display 5 Continue holding the Start button down for at least CAUTION Ingesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or o...

Страница 11: ...ends of the Carbon Cartridge before inserting into the Carbon Filter Housing Place the Carbon Cartridge into the Housing and screw the Housing up into the Filter Housing Cap 5 Slowly open the inlet w...

Страница 12: ...drains 5 When the water flow out of the strainer stops pour the liquid bleach into the strainer Be care ful not to spill bleach onto clothing or skin You may want to add the bleach using a cup or fun...

Страница 13: ...ater After a certain period of time depending upon water quality the filter has to be cleaned This is accom plished through the Flush Duration Mode During this mode the drain valve opens and flushes t...

Страница 14: ...and release start but ton to view current setting Figure 7 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 8 4 After ten seconds...

Страница 15: ...ter fifty minutes they are displayed in hours Table B TO SET Fd FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure...

Страница 16: ...for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasi...

Страница 17: ...hange the Carbon Filter Cartridge follow the steps under Install and Flush the Carbon Filter Cartridge in the Installation section of this manual CHANGING THE CAPILLARY MEMBRANE FILTER CARTRIDGE 1 Ope...

Страница 18: ...exceeded it s filtration capacity Replace the Carbon Cartridge Filter Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken capillary i...

Страница 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...

Страница 20: ...ousing 10 1 7 1001149 Label Shroud 1 8 2090139 Cartridge Carbon Block 1 9 3080103 Screw MACH 8 32 x 1 4 1 Item Part Description Qty No Item Part Description Qty No SLTRSHD 10 1001083 Label Drain 1 11...

Страница 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...

Страница 22: ...984 Mounting Bracket 2 1 15 2090120 Cartridge Filter 2 x 16 1 16 2180173 Connector Slide 2 2 17 2180177 Cap End 2 2 18 0200219 O Ring 2 4 19 2190133 Tee Strainer 1 2 NPT 1 20 2090129 Screen Tee Strain...

Страница 23: ...P N 1010885 07 04 WIRING DIAGRAM TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFI...

Страница 24: ...zed service agency to reach the equipment location 2 Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to...

Отзывы: