Programming Timer 

NOTE: Once the UF-216 unit is powered up, the 

LED display cycles through the default or current 

settings: Flush Duration (Fd) and its setting will 

be followed by Flush Interval (Fi) and its settings. 

At any time during this sequence, which lasts 

approximately 30 seconds the UF-216 unit can be 

programmed.

 

Setting the Flush Interval (Fi)

   1.  When 

Fi 

(Figure 5) is displayed, press and 

release start button to view current setting .

   2.  To make a change, press and hold down start 

button to scroll through settings - release button 

at desired setting (Figure 6).

   3.  After ten seconds, unless start button is 

depressed, unit automatically returns to 

Flush Interval Mode.

NOTE: Fi times are displayed in ten minute inter-

vals, after fifty minutes they are displayed in hours 

(Table A). 

Filtration Process

Water filtration in the UF-216 is accomplished using 

two modes: Flush Interval Mode, shown as 

Fi 

on the 

LED Display and Flush Duration Mode (

Fd 

on LED dis-

play). During the Flush Interval, water enters the inlet 

and flows through the filter element before exiting the 

Permeate outlet as usable product water. 

After a certain period of time, depending upon water 

quality, the filter has to be cleaned. This is accom-

plished through the Flush Duration Mode. During 

this mode, the drain valve opens and flushes the

membrane to remove debris collected inside the 

membrane walls. 

NOTE: Both the Flush Interval Mode and the Flush 

Duration  Mode can be automated by programming 

the timer. During the Flush Interval Mode, the valve 

is not powered in order to keep water filtering during 

a power outage.

Figure 4. LED Display, Front Panel

LED Display 

Fi 

-  Flush Interval Mode is the time between flushes  

        and is displayed in minutes or hours. 

Fd 

- Flush Duration Mode is the amount of time used  

        to flush and remove debris from filter cartridge and  

        is displayed in seconds. 

FL 

- Manual Flush Mode operation, solenoid is 

       manually activated by the user.

Starting the System

Power up the unit. 

The LED read-out displays the following for about two 

seconds each:

1.  

8.8  

2.  

Fd 

followed by its time settings in seconds.

3.  

Fi 

and its time setting, in minutes or hours. 

      The 

Fd

Fi 

sequence repeats for 30 seconds  

      after which, the unit automatically returns to the  

      Flush Interval Mode (

Fi

). The time setting for 

Fi 

      will be displayed and the decimal point will flash in  

      one second intervals. 

NOTE: The timer can be programmed immediately 

after start-up or while in Flush Interval Mode. 

OPERATION

Содержание UF-216C Series

Страница 1: ...WATER FILTRATION SYSTEM UF 216C Series Owner s Manual P N 1010885 07 04 MANUFACTURING NUMBERS 9700405...

Страница 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and ar...

Страница 3: ...afety the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this...

Страница 4: ...TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a prope...

Страница 5: ...ualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cart...

Страница 6: ...UF 216 WATER FILTRATION SYSTEM 6 P N 1010885 07 04 SPECIFICATIONS continued Figure 2a Components Components Inlet Nipple Permeate Nipple Drain Nipple Power Cord Shroud...

Страница 7: ...UF 216 WATER FILTRATION SYSTEM 7 P N 1010885 07 04 LED Display Program Button Power Cord Filter Cartridge Strainer Permeate Drain Inlet Figure 2b Components SPECIFICATIONS continued Components...

Страница 8: ...r to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or Teflon tape on pipe threads Be careful not to get the pipe sealant inside the pipe when making t...

Страница 9: ...line Check with local codes for the proper specification DRAIN LINE PLUMBING The drain line is used to flush away the particle buildup when cleaning the filter The drain line must be able to support...

Страница 10: ...nd FL will appear on the display 5 Continue holding the Start button down for at least CAUTION Ingesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or o...

Страница 11: ...ends of the Carbon Cartridge before inserting into the Carbon Filter Housing Place the Carbon Cartridge into the Housing and screw the Housing up into the Filter Housing Cap 5 Slowly open the inlet w...

Страница 12: ...drains 5 When the water flow out of the strainer stops pour the liquid bleach into the strainer Be care ful not to spill bleach onto clothing or skin You may want to add the bleach using a cup or fun...

Страница 13: ...ater After a certain period of time depending upon water quality the filter has to be cleaned This is accom plished through the Flush Duration Mode During this mode the drain valve opens and flushes t...

Страница 14: ...and release start but ton to view current setting Figure 7 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 8 4 After ten seconds...

Страница 15: ...ter fifty minutes they are displayed in hours Table B TO SET Fd FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure...

Страница 16: ...for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasi...

Страница 17: ...hange the Carbon Filter Cartridge follow the steps under Install and Flush the Carbon Filter Cartridge in the Installation section of this manual CHANGING THE CAPILLARY MEMBRANE FILTER CARTRIDGE 1 Ope...

Страница 18: ...exceeded it s filtration capacity Replace the Carbon Cartridge Filter Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken capillary i...

Страница 19: ...UF 216 WATER FILTRATION SYSTEM 19 P N 1010885 07 04 REPLACEMENT PARTS UF 216...

Страница 20: ...ousing 10 1 7 1001149 Label Shroud 1 8 2090139 Cartridge Carbon Block 1 9 3080103 Screw MACH 8 32 x 1 4 1 Item Part Description Qty No Item Part Description Qty No SLTRSHD 10 1001083 Label Drain 1 11...

Страница 21: ...UF 216 WATER FILTRATION SYSTEM 21 P N 1010885 07 04 REPLACEMENT PARTS UF 216 continued...

Страница 22: ...984 Mounting Bracket 2 1 15 2090120 Cartridge Filter 2 x 16 1 16 2180173 Connector Slide 2 2 17 2180177 Cap End 2 2 18 0200219 O Ring 2 4 19 2190133 Tee Strainer 1 2 NPT 1 20 2090129 Screen Tee Strain...

Страница 23: ...P N 1010885 07 04 WIRING DIAGRAM TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105 C UNLESS OTHERWISE SPECIFI...

Страница 24: ...zed service agency to reach the equipment location 2 Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to...

Отзывы: