Showmaster Overview
Medialon Showmaster User Manual
p 26 of 42
M569-3 | June 2023
DMX Connection
Medialon Showmaster Pro is provided with 2 DMX 512 ports that can be used for input or output
(software configurable in the Resource Setup).
Pin Connection
1
Ground
2
Data –
3
Data +
4
NC
5
NC
Timecode Connection
Medialon Showmaster Pro is provided with 1 Timecode balanced input port and 1 Timecode
balanced output port.
Pin Connection
1
Cable shield
2
3
Signal –
Serial Connection
Medialon Showmaster V2 Pro is provided with 8 serial ports.
Showmaster Pro is configured with DTE serial ports. Use a crossover (null modem) cable when
you want to connect to a computer.
2.4.5
Rack Mount
WARNING – The unit is intended to be rack-mounted as per applicable requirements so no
imbalance of internal components is likely to occur. Adequate airflow clearance is to be provided
so ambient temperature does not exceed the limit.
•
Please refer to document:
M562 Medialon Safety Instructions
for installation, use and service.