Showmaster Overview
Medialon Showmaster User Manual
p 28 of 42
M569-3 | June 2023
•
Input Resistance: 1.8 k
Ω
in series with opto-coupler
•
Filter Response Times: Rise Time = 4.7 mS / Fall Time = 4.7 mS
•
Non-Filter Response Times: Rise Time = 10
µ
S / Fall Time = 30
µ
S
•
Connector: Sub-D 37 – type Male
Relay Outputs:
•
Number
: 16 SPDT form C Relays
•
Contact Type
: Single crossbar; Ag with Au clad
•
Rated Load AC
: 0.5 A at 125 V AC (62.5 VA max.)
•
Rated Load DC
: 1 A at 24 V DC (30 W max.)
•
Max. Switching Voltage: 125 V AC, 60 V DC
•
*Max. Switching Current: 1 A
•
Contact Resistance: 100 m
Ω
max.
•
Contact Life
: 5 million operations min.
•
Operating Time: 5 mS max.
•
Release Time: 5 mS max.
•
Connector
: Sub-D 37 – type Female
When using Breakout boxes (SWM_BO_KIT), the maximum electrical specifications are 150 mA /
12 V DC per relay with a maximum of 2 A for the whole 16 relays.
Power Required:
•
5 V@ 30 mA typical (all relays off, add 30 mA per relay)
•
5 V@ 510 mA typical (all relays ON)
DMX Interface
•
Number
: 2 DMX512 Input or Output
•
Connector
: XLR 5 pin – type Female
TimeCode Interface
•
Number
: 1 Balanced Timecode Input (Female), 1 Balanced Timecode Output (Male)
•
Connector
: XLR 3 pin
•
Format
: SMPTE