Showmaster Overview
Medialon Showmaster User Manual
p 15 of 42
M569-3 | June 2023
DMX Connection
Medialon Showmaster LE is provided with a DMX 512 output.
Pin Connection
1
Ground
2
Data –
3
Data +
4
NC
5
NC
Serial Connection
Medialon Showmaster LE is provided with 2 serial ports.
Showmaster LE is configured with DTE serial ports. Use a crossover (null modem) cable when
you want to connect to a computer.
2.3.5
Rack Mount
WARNING – The unit is intended to be rack-mounted as per applicable requirements so no
imbalance likely to occur to the internal components. Adequate clearance for airflow should be
provided on both sides so ambient temperature does not exceed the limit.
•
Please refer to document:
M562 Medialon Safety Instructions
for installation, use and service.
Installation
NOTE You need a #2 Phillips screwdriver for rack mount installation. Complete the following
steps to mount devices in a rack:
•
Remove the rack mount kit from the shipping carton. The kit contains two L-shaped mounting
brackets and four sink-head screws.
•
Using a Phillips screwdriver, attach the mounting brackets to the sides of the device using four
sink-head screws.
•