Showmaster Overview
Medialon Showmaster User Manual
p 24 of 42
M569-3 | June 2023
Signal
PIN #
Signal
PIN #
Signal
PIN #
Isolated Input 1A
1
Isolated Input 7A
7
Isolated Input 13A
13
Isolated Input 1B
20
Isolated Input 7B
26
Isolated Input 13B
32
Isolated Input 2A
2
Isolated Input 8A
8
Isolated Input 14A
14
Isolated Input 2B
21
Isolated Input 8B
27
Isolated Input 14B
33
Isolated Input 3A
3
Isolated Input 9A
9
Isolated Input 15A
15
Isolated Input 3B
22
Isolated Input 9B
28
Isolated Input 15B
34
Isolated Input 4A
4
Isolated Input 10A
10
Isolated Input 16A
16
Isolated Input 4B
23
Isolated Input 10B
29
Isolated Input 16B
35
Isolated Input 5A
5
Isolated Input 11A
11
No Connection
17
Isolated Input 5B
24
Isolated Input 11B
30
No Connection
36
Isolated Input 6A
6
Isolated Input 12A
12
No Connection
18
Isolated Input 6B
25
Isolated Input 12B
31
No Connection
19
No Connection
37
Relay Output Connector
Medialon Showmaster V2 Pro’s relay outputs are comprised of sixteen SPST electromechanical
relays. All relays are de-energized at power-on.
Relay outputs are connected to Showmaster V2 via a SubD 37 pin Female connector. The wiring
may be directly from signal sources or through our optional Breakout Box wiring terminal
(SWM_BO_KIT). Pin assignments follow.
+
DC
−
Relay X NO
SHOWMASTER
Relay X Common
Indicator