Rebuilding a RAID 5 disk array
www.3ware.com
43
Auto rebuild of a mirrored or RAID 5 array
If a hot spare is specified and the mirrored or RAID 5 array degrades, an event
notification is generated and the hot spare dynamically replaces the failed
drive in the array without user intervention. Rebuild will automatically be
launched as a background process and an event notification will notify the
user when the rebuild process is complete.
Auto initialization on power failure
A power failure will cause the secondary drive of a mirrored unit (RAID 1 or
10) to degrade. To make sure that the information on both drives is accurate,
initialization of the unit starts automatically in the background. When the
initialization is complete, the two halves of the mirror are redundant again.
3ware’s auto-init feature determines if this is required. During driver startup, a
flag is set that indicates that the driver loaded. Upon an orderly shutdown, the
flag is rewritten, indicating that there was a clean shutdown. During the next
system power cycle the firmware queries the flag. If there was a power
failure, the flag will indicate that there was not a clean shutdown. This means
that the data on the drives may not be correct
For a RAID 5 configuration, if the process encounters the flag setting that
indicates a power failure, the firmware automatically starts the background
initialization process to calculate and write the parity information.
Cancelling and restarting a rebuild with a new drive
Currently, a rebuild can be paused using the scheduling feature in 3DM, but
cannot be cancelled using the 3DM software. However, a rebuild can be
aborted by physically removing the disk used to replace the degraded drive.
Abort a rebuild by following the applicable procedure below.
If your system has hot swap carriers:
1
Remove the disk while the system is powered. The rebuild will be imme-
diately aborted.
2 Go to the Configure screen in 3DM and click the box in front of the disk
drive that was removed. Click on Remove Drive.
3 Add another drive and click on the box in front of this port. Click on Add
Drive. The drive is called “RAID Disk”.
4 Click the boxes in front of the RAID Disk and the degraded array. Select
Rebuild. The rebuild starts with the new disk drive.
If your system does not have hot swap carriers:
1
Power down the system and remove the disk drive that caused the array to
become degraded.
Содержание 3W-7410 - Escalade 7410 RAID Controller
Страница 6: ...iv 3ware Escalade ATA RAID Controller User Guide ...
Страница 14: ...Before You Begin 6 3ware Escalade ATA RAID Controller User Guide ...
Страница 22: ...Quick Installation Guide 14 3ware Escalade ATA RAID Controller User Guide Quick Installation Guide ...
Страница 24: ...Quick Installation Guide 16 3ware Escalade ATA RAID Controller User Guide ...
Страница 68: ...Windows Installation 60 3ware Escalade ATA RAID Controller User Guide ...
Страница 86: ...FreeBSD Installation 78 3ware Escalade ATA RAID Controller User Guide ...
Страница 104: ...3DM Disk Management Utility 96 3ware Escalade ATA RAID Controller User Guide ...
Страница 116: ...Troubleshooting Problems and Solutions 108 3ware Escalade ATA RAID Controller User Guide ...
Страница 122: ...Appendix B Warranty Technical Support and Service 114 3ware Escalade ATA RAID Controller User Guide ...
Страница 126: ...Index 118 3ware Escalade ATA RAID Controller User Guide ...